This XPSLCM Safety control unit for muting function of type 2 and type 4 Safety Light Curtain provides integral LEDs, which offer a local Signaling for clearly display of device’s status. Its B10D reliability data is 800 000. When associated and correctly connected to an appropriate safety control unit, it conforms to Category 4, performance level PL e, SILCL 3 as described in EN/ISO 13849-1, EN/IEC 62061. It is compatible with Through-beam photoelectric sensor dark-on operate (PNP), Polarized reflex photoelectric sensor, Reflex photoelectric sensor.
Brand: Telemecanique
Add to Quote CataloguePart Number | XPSLCMUT1160 |
---|---|
Country of Origin | IT |
UPC | 785901993209 |
UPC11 | 78590199320 |
EAN | 3389119618717 |
Availability | N |
Lead Time | 24 |
UNSPSC | 32151804 |
HTs Code | 8536410020 |
Prop 65 | This product can expose you to chemicals including: Di-isodecyl phthalate (DIDP) and Diisononyl phthalate (DINP) which is known to the State of California to cause Carcinogen and Reproductive harm. For more information go to www.p65warnings.ca.gov |
RoHS Compliant | Yes |
Discount Schedule | DS2 |
Return Indicator | No |
Depth | 4.51 inch |
Height | 3.90 inch |
Width | 1.38 inch |
Weight | 0.33 pound |
Range Of Product | Preventa Safety automation |
---|---|
Product Or Component Type | Preventa safety module |
Safety Module Name | XPSLCM |
Safety Module Application | For the muting function of type 2 and type 4 safety light curtains monitored |
Function Of Module | Muting |
Safety Level | Can reach PL = e with the appropriate control system and correctly wired EN/ISO 13849-1 Can reach category 4 with the appropriate control system and correctly wired EN/ISO 13849-1 Can reach SILCL 3 with the appropriate control system and correctly wired EN/IEC 62061 |
Safety Reliability Data | PFHd = 6.42E-9...5.03E-8 1/h EN/IEC 62061 B10d = 800000 EN/ISO 13849-1 MTTFd = 26...100 years EN/ISO 13849-1 DC = 96.2...98.9 % EN/ISO 13849-1 |
Synchro Time Between Inputs | 4 s muting |
Connections - Terminals | Screw terminal |
Output Type | 2 relay, 2 A 24 V |
Number Of Additional Circuits | 1 solid state PNP (NO), 100 mA status 24 V 1 solid state PNP (NO), 20.8…208 mA lamp 24 V |
Us Rated Supply Voltage | 24 V DC - 20...20 % |
Muting Maximum Duration | 30 s or unlimited |
Marking | CE |
Power Consumption In W | 5 W |
Number Of Controlled Devices | 1 |
Number Of Inputs | 2 per muting function) |
Sensor Power Supply | 24 V |
Max Sensor Supply Current | 10 mA |
Input Compatibility | Through beam photoelectric sensor dark-on operate(PNP) Polarised reflex photoelectric sensor Reflex photoelectric sensor |
Response Time On Input Open | 20 ms |
Ui Rated Insulation Voltage | 300 VEN 50178 |
Uimp Rated Imp Wstd Voltage | 4 kV II EN 50178 |
Local Signalling | 6 LEDs |
Mounting Support | 35 mm symmetrical DIN rail |
Depth | 4.51 in (114.5 mm) |
Height | 3.90 in (99 mm) |
Width | 1.38 in (35 mm) |
Product Weight | 0.33 lb(US) (0.15 kg) |
Standards | EN/ISO 13849-1 EN/IEC 62061 |
Product Certifications | TÜV CULus |
IP Degree Of Protection | IP2x IEC 60529 |
Ambient Air Temp For Op | 32…131 °F (0…55 °C) |
Ambient Air Temp For Storage | -13…158 °F (-25…70 °C) |
Category | 22455 - LIGHT CURTAINS - XUSL |
Discount Schedule | DS2 |
GTIN | 00785901993209 |
Nbr. Of Units In Pkg. | 1 |
Country Of Origin | IT |
Green Premium Status | Green Premium product |
REACh Free Of SVHC | Yes |
EU RoHs Directive | Pro-active compliance (Product out of EU RoHS legal scope) |
Toxic Heavy Metal Free | Yes |
Mercury Free | Yes |
Warranty | 18 months |