This XPSCM safety module is for monitoring of single-beam photo-electric sensors and has a built-in “muting” function. It meets the requirements of PL c/Category 2 conforming to EN/ISO 13849-1.and SILCL1 conforming to EN/IEC 61508 and EN/IEC 62061. Used in conjunction with XU2S single-beam photo-electric sensors (periodically tested), it establishes a category 2 light curtain conforming to IEC/EN 61496 parts 1 and 2.
Brand: Telemecanique
Add to Quote CataloguePart Number | XPSCM1144P |
---|---|
Country of Origin | ID |
UPC | 785901756378 |
UPC11 | 78590175637 |
EAN | 3389110274134 |
Availability | S |
Lead Time | 55 |
UNSPSC | 32151802 |
HTs Code | 8541408000 |
Prop 65 | This product can expose you to chemicals including: Lead and lead compounds which is known to the State of California to cause Carcinogen & Reproductive harm. For more information go to www.p65warnings.ca.gov |
RoHS Compliant | Yes |
Discount Schedule | SAF2 |
Return Indicator | Yes |
Range Of Product | Preventa Safety detection |
---|---|
Product Or Component Type | Safety module |
Safety Module Name | XPSCM |
Safety Module Application | For monitoring of single beam photo-electric sensor |
Function Of Module | Built-in muting |
Safety Level | Can reach category 2 with the appropriate control system and correctly wired EN/ISO 13849-1 Can reach SILCL 1 with the appropriate control system and correctly wired EN/IEC 62061 Can reach PL = c with the appropriate control system and correctly wired EN/ISO 13849-1 |
Safety Reliability Data | MTTFd = 16.6 years EN/ISO 13849-1 DC = 95.5 % EN/ISO 13849-1 PFH = 3.12E-7 1/h EN/IEC 61508 PFHd = 3.12E-7 1/h EN/IEC 62061 |
Number Of Inputs | 2 MA, MB)muting function 4 Z1, Z2, Z3, Z4)sensor |
Input Voltage | 24 V DCsensor 24 V DC U+, U-)muting function |
Input Compatibility | XC limit switch muting function XU2M18PP340... muting function XU2S18PP340... (infrared) sensor XU9M18PP340... muting function |
Connections - Terminals | Captive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² solid or flexible without cable end Captive screw clamp terminals, removable terminal block, 1 x 0.25...1 x 2.5 mm² flexible with cable end, with bezel Captive screw clamp terminals, removable terminal block, 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel Captive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1 mm² solid without cable end Captive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1.5 mm² flexible without cable end Captive screw clamp terminals, removable terminal block, 2 x 0.25...2 x 1 mm² flexible with cable end, without bezel Captive screw clamp terminals, removable terminal block, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel |
Output Type | Relay 2 NO 13-14, 23-24), volt-free |
Us Rated Supply Voltage | 24 V DC - 20...20 % |
Sensor Power Supply | U+, U- 24 V DC |
Supply Current For Sensors | 200 mA |
Input Current | 200 mA muting function |
Synchro Time Between Inputs | 3 s +/- 20 %) for the activation of the MA/MB muting signal |
Muting Maximum Duration | 60 s - 10...30 %) |
Line Resistance | 10 Ohm sensor power supply |
Breaking Capacity | 180 VA holding AC-15 C300 relay output 1800 VA inrush AC-15 C300 relay output |
Breaking Capacity | 20 mA 24 V solid state output 1.5 A 24 V DC-13)50 ms relay output |
Associated Fuse Rating | 4 A gG relay output DIN VDE 0660 part 200 4 A gG relay output EN/IEC 60947-5-1 6 A fast blow relay output DIN VDE 0660 part 200 6 A fast blow relay output EN/IEC 60947-5-1 |
Minimum Output Current | 10 mA relay output |
Minimum Output Voltage | 17 V relay output |
Response Time On Input Open | 25 ms |
Local Signalling | 1 LED electronic internal fuse status 1 LED restarting 1 LED safety outputs closed 1 LED safety outputs open 1 incandescent lamp muting 4…6.5 W |
Output Thermal Current | 5.6 A per relay 11 A maximum |
Power Consumption In W | 15 W |
Protection Type | Electronic internal fuse |
Ui Rated Insulation Voltage | 300 V 2)DIN VDE 0110 parts 1 and 2 300 V 2)EN/IEC 60947-5-1 |
Uimp Rated Imp Wstd Voltage | 4 kV III DIN VDE 0110 parts 1 and 2 4 kV III EN/IEC 60947-5-1 |
Ambient Air Temp For Op | 14…131 °F (-10…55 °C) |
Ambient Air Temp For Storage | -13…185 °F (-25…85 °C) |
IP Degree Of Protection | IP20 IEC 60529 terminals) IP40 IEC 60529 enclosure) |
Category | 22477 - SAFETY MODULES (PREVENTA) |
Discount Schedule | SAF2 |
GTIN | 00785901756378 |
Nbr. Of Units In Pkg. | 1 |
Country Of Origin | ID |
Green Premium Status | Green Premium product |
EU RoHs Directive | Pro-active compliance (Product out of EU RoHS legal scope) |
Mercury Free | Yes |
WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
Pvc Free | Yes |
Warranty | 18 months |
Powered by
Based on 2 User Reviews
1619 Boyd St, Santa Ana, CA 92705
(714) 835-6211
(714) 972-2366