This Zelio Logic SR3 discovery pack compact smart relay / programmable controller uses a supply voltage of 100V to 240V alternating current. It has 26 inputs / outputs with screw-clamp terminals and has an integrated LCD display. It also offers simple programming, display and diagnosing of malfunctions display and navigation buttons. This discovery package includes one copy of Zelio Soft and one USB cable to connect the relay to your PC. Its simple ladder programming makes it adapted for non-specialists.
Add to Quote CataloguePart Number | SR3PACK2FU |
---|---|
Country of Origin | FR |
UPC | 785901571926 |
UPC11 | 78590157192 |
EAN | 3389110550054 |
Availability | S |
Lead Time | 33 |
UNSPSC | 39122331 |
ECCN | EAR99 |
HTs Code | 8536490080 |
Prop 65 | This product can expose you to chemicals including: Lead and lead compounds which is known to the State of California to cause Carcinogen & Reproductive harm. For more information go to www.p65warnings.ca.gov |
RoHS Compliant | Yes |
Discount Schedule | I |
Return Indicator | Yes |
Weight | 1.87 pound |
Range Of Product | Zelio Logic |
---|---|
Product Or Component Type | Modular discovery packs |
Discrete Input Number | 16 |
Number Of Outputs | 10 relay |
Kit Composition | Cable PC SR2USB01 for connection to PC SR3B261FU Zelio Soft 2 programming software CD-ROM |
Input/Output Number | 26 |
Local Display | With |
Number Or Control Scheme Lines | 120 ladder 0…200 FBD |
Cycle Time | 6…90 ms |
Backup Time | 10 years 77 °F (25 °C) |
Clock Drift | 12 min/year 32…131 °F (0…55 °C) 6 s/month 77 °F (25 °C) |
Checks | Program memory on each power up |
Us Rated Supply Voltage | 100...240 V |
Supply Voltage Limits | 85…264 V |
Supply Frequency | 50/60 Hz |
Supply Current | 100 mA 100 V without extension) 50 mA 240 V without extension) 60 mA 240 V with extensions) 80 mA 100 V with extensions) |
Power Consumption In Va | 12 VA without extension 17 VA with extensions |
ISOlation Voltage | 1780 V |
Protection Type | Against inversion of terminals (control instructions not executed) |
Discrete Input Voltage | 100...240 V AC |
Discrete Input Current | 0.6 mA |
Discrete Input Frequency | 47...53 Hz 57...63 Hz |
Voltage State 1 Guaranteed | >= 79 V discrete input |
Voltage State 0 Guaranteed | <= 40 V discrete input |
Current State 1 Guaranteed | >= 0.17 mA discrete input) |
Current State 0 Guaranteed | <= 0.5 mA discrete input) |
Input Impedance | 350 kOhm discrete input |
Output Voltage Limits | 5...30 V DC relay output) 24...250 V AC |
Contacts Type And Composition | NO relay output |
Output Thermal Current | 5 A for 2 outputs relay output 8 A for 8 outputs relay output |
Electrical Durability | AC-12 500000 cycles 230 V, 1.5 A relay output EN/IEC 60947-5-1 AC-15 500000 cycles 230 V, 0.9 A relay output EN/IEC 60947-5-1 DC-12 500000 cycles 24 V, 1.5 A relay output EN/IEC 60947-5-1 DC-13 500000 cycles 24 V, 0.6 A relay output EN/IEC 60947-5-1 |
Switching Capacity In Ma | >= 10 mA 12 V relay output) |
Operating Rate In Hz | 0.1 Hz at Ie)relay output 10 Hz no load)relay output |
Mechanical Durability | 10000000 cycles relay output |
Uimp Rated Imp Wstd Voltage | 4 kVEN/IEC 60947-1 and EN/IEC 60664-1 |
Clock | With |
Response Time | 50 ms ladder from state 0 to state 1)discrete input 50 ms ladder from state 1 to state 0)discrete input 50...255 ms FBD from state 0 to state 1)discrete input 50...255 ms FBD from state 1 to state 0)discrete input 10 ms from state 0 to state 1)relay output 5 ms from state 1 to state 0)relay output |
Connections - Terminals | screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 25...AWG 14) semi-solid screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 25...AWG 14) solid screw terminals, 1 x 0.25...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) solid screw terminals, 2 x 0.25...2 x 0.75 mm² AWG 24...AWG 18) flexible with cable end |
Tightening Torque | 4.43 lbf.in (0.5 N.m) |
Overvoltage Category | III EN/IEC 60664-1 |
Product Weight | 1.87 lb(US) (0.85 kg) |
Immunity To Microbreaks | 10 ms |
Product Certifications | GL UL C-tick CSA GOST |
Standards | EN/IEC 61000-4-5 EN/IEC 61000-4-2 level 3 EN/IEC 60068-2-27 Ea EN/IEC 61000-4-3 EN/IEC 60068-2-6 Fc EN/IEC 61000-4-6 level 3 EN/IEC 61000-4-11 EN/IEC 61000-4-4 level 3 EN/IEC 61000-4-12 |
IP Degree Of Protection | IP20 IEC 60529 terminal block) IP40 IEC 60529 front panel) |
Environmental Characteristic | EMC directive EN/IEC 61000-6-2 EMC directive EN/IEC 61000-6-3 EMC directive EN/IEC 61000-6-4 EMC directive EN/IEC 61131-2 zone B low voltage directive EN/IEC 61131-2 |
Disturbance Radiated/Conducted | Class B EN 55022-11 group 1 |
Pollution Degree | 2 EN/IEC 61131-2 |
Ambient Air Temp For Op | -4…104 °F (-20…40 °C) in non-ventilated enclosure IEC 60068-2-1 and IEC 60068-2-2 -4…131 °F (-20…55 °C) IEC 60068-2-1 and IEC 60068-2-2 |
Ambient Air Temp For Storage | -40…158 °F (-40…70 °C) |
Powered by
Based on 2 User Reviews
1619 Boyd St, Santa Ana, CA 92705
(714) 835-6211
(714) 972-2366