Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
Modicon TM3 Safety module – 3 Function, Cat 4 PL e/SIL CL3 (spring) 24Vdc
TM3SAK6RG
Modicon TM3 Safety module – 3 Function, Cat 4 PL e/SIL CL3 (spring) 24Vdc

This TM3 safety expansion module monitors emergency shutdown pushbuttons, limit switches, light curtains and safety mats/edges. It meets the requirements of PL e/Category 4 conforming to EN/ISO 13849-1 and SILCL3 conforming to EN/IEC 62061. It has a module locking latch, 2 TM3 bus connectors designed to provide continuity of the link between connected modules, a symmetrical rail locking clip, display block for the module channels and diagnostics. It completes your Modicon M221, M241 or M251 PLC configuration with a dedicated safety I/O, without the need to use a complete safety controller. It has removable terminals for easier and better control wires tightening, thus improving installation reliability. It is compatible with emergency push buttons, limit switches, safety light curtains and safety mats/edges, the 4 most common safety sensors in the industry. It has spring terminals for fast and reliable wiring of safety circuits.

Add to Quote Catalogue
Specifications
Part Number TM3SAK6RG
Country of Origin DE
UPC 785901967101
UPC11 78590196710
EAN 3606485393049
Availability N
Lead Time 24
UNSPSC 32151705
ECCN EAR99
HTs Code 8538908180
Prop 65 This product can expose you to chemicals including: Lead and lead compounds which is known to the State of California to cause Carcinogen & Reproductive harm. For more information go to www.p65warnings.ca.gov
RoHS Compliant Yes
Discount Schedule MSX
Return Indicator No
Depth 2.87 inch
Height 3.70 inch
Width 1.72 inch
Weight 0.42 pound
Characteristics
Range Of Product Modicon TM3 Safety
Product Or Component Type Safety module
Device Short Name TM3SAK
Safety Module Application For emergency stop, switch, sensing mat/edges or safety light curtain monitoring
Function Of Module Emergency stop monitoring 1-channel wiring Emergency stop monitoring 2-channel wiring Monitoring of a movable guard with 2 switches and automatic start Monitoring of a movable guard Multiple emergency stop monitoring 2-channel wiring Proximity sensor monitoring PNP/PNP Proximity sensor monitoring PNP/NPN Sensing mat and edges monitoring Monitoring of electro-sensitive protection equipment (ESPE) PNP/PNP Monitoring of electro-sensitive protection equipment (ESPE) PNP/NPN
Safety Level Can reach PL e/category 4 EN/ISO 13849-1 2008 Can reach PL e/category 4 EN/ISO 13849-2 2012 Can reach SILCL 3 EN/IEC 62061 2005 Can reach SIL 3 EN/IEC 61508 2010
Safety Reliability Data DC = 95 % EN/ISO 13849-1 PFHd = 5E-9 1/h IEC 61508-1 1 operation/hour DC-13 24 V DC, <4 A PFHd = 30E-9 1/h IEC 61508-1 60 operations/hour DC-13 24 V DC, <1 A MTTFd = 500 years EN/ISO 13849-1 1 operation/hour DC-13 24 V DC, <4 A MTTFd = 85 years EN/ISO 13849-1 60 operations/hour DC-13 24 V DC, <1 A SFF = 95 % IEC 61508-1 HFT = 1 IEC 61508-1 Type = A IEC 61508-1
Synchro Time Between Inputs Unlimited 2 or 4 s depending of wiring configurable by software
Connections - Terminals Captive spring terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² flexible without cable end 13-14, 23-24, 33-34 Captive spring terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² solid without cable end 13-14, 23-24, 33-34 Captive spring terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible with cable end, with bezel 13-14, 23-24, 33-34 Captive spring terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel 13-14, 23-24, 33-34 Captive spring terminals, removable terminal block 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel 13-14, 23-24, 33-34 Captive spring terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² flexible without cable end other terminals Captive spring terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² solid without cable end other terminals Captive spring terminals, removable terminal block 1 x 0.25...1 x 0.5 mm² flexible with cable end, with bezel other terminals Captive spring terminals, removable terminal block 1 x 0.25...1 x 1.5 mm² flexible with cable end, without bezel other terminals
Output Type Relay instantaneous opening, 3 NO, potential free
Number Of Safety Circuits 3 NO relay instantaneous opening
Maximum Switching Voltage 230 V AC-15 50 Hz relay instantaneous opening) 24 V DC-13 relay instantaneous opening)
[Us] Rated Supply Voltage 24 V - 15...20 % DC
Power Consumption In W 0.2 W 5 V DC 3.6 W 24 V DC
Input Protection Type Internal, electronic
Uc Control Circuit Voltage 24 V DC
Cable Distance Between Devices 98.43 ft (30 m)
Breaking Capacity 360 VA holding AC-15 B300 relay output 3600 VA inrush AC-15 B300 relay output
Breaking Capacity 4 A 24 V 50 ms DC-13 relay output
Output Thermal Current 6 A per relay relay output
Ith Cnvtl Free Air Therm Crrt 18 A
Associated Fuse Rating 4 A gG or gL relay output EN/IEC 60947-5-1 6 A fast blow relay output EN/IEC 60947-5-1
Minimum Output Current 10 mA relay output
Output Voltage 10 V relay output
Response Time On Input Open 40 ms
Ui Rated Insulation Voltage 300 V 2)IEC 60647-5-1
Uimp Rated Imp Wstd Voltage 4 kV III IEC 60647-5-1
Current Consumption 100 mA 24 V DC external supply
Local Signalling User 8 LEDs green/red)
Electrical Connection Spring terminal
Product Compatibility Safety light curtains EN/IEC 61496-1 (type 4) Sensing mat/edges EN 1760-1
Standards EN/ISO 13849-1:2008 EN/ISO 13849-2:2012 EN/IEC 62061:2005 EN/IEC 61508:2010 EN/IEC 60947-5-1:2010 EN/IEC 61131-2:2007 EN/IEC 60204-1:2005 EN/IEC 60204-1:2009/A1 IEC 61010-1:2010 EN 50581:2012
Product Certifications CSA 61010-2-201 (pending) TÜV CSA Haz Loc Class 1 Division 2 (pending) EAC RCM UL 61010-2-201 ANSI Haz Loc Class 1 Division 2 (pending)
Marking CSA REACH RCM UL EFUP 10 CE TÜV EAC
Electromagnetic Compatibility Electrostatic discharge immunity test 8 kV air discharge) EN/IEC 61000-4-2 Electrostatic discharge immunity test 6 kV contact discharge) EN/IEC 61000-4-2 Susceptibility to electromagnetic fields 10 V/m 80 MHz to 1 GHz) EN/IEC 61000-4-3 Susceptibility to electromagnetic fields 3 V/m 1.4 GHz...2 GHz) EN/IEC 61000-4-3 Susceptibility to electromagnetic fields 1 V/m 2 GHz...3 GHz) EN/IEC 61000-4-3 Magnetic field at power frequency 30 A/m 50...60 Hz) EN/IEC 61000-4-8 Electrical fast transient/burst immunity test 3 kV power lines (DC)) EN/IEC 61000-4-4 Electrical fast transient/burst immunity test 2 kV I/O) EN/IEC 61000-4-4 1.2/50 µs shock waves immunity test 1 kV power lines (DC)) EN/IEC 61000-4-5 Conducted RF disturbances 10 V 0.15...80 MHz) EN/IEC 61000-4-6 Radiated emission 40 dBµV/m 24 V)class A EN 55011 Radiated emission 47 dBµV/m 24 V)class A EN 55011
Mounting Support Top hat type TH35-7.5 rail IEC 60715 Top hat type TH35-15 rail IEC 60715 wall mount using attached fasteners
Height 3.70 in (94 mm)
Depth 2.87 in (73 mm)
Width 1.72 in (43.7 mm)
Product Weight 0.42 lb(US) (0.19 kg)
Standards EN 1088/ISO 14119 EN/IEC 60947-5-1 EN/IEC 60947-1 EN 60204-1 EN/ISO 13850
Resist Electrostatic Dischrg 8 kV in air EN/IEC 61000-4-2 6 kV on contact EN/IEC 61000-4-2
Resist To Electromagn Fields 9.14 V/m (10 V/m) 80 MHz...1 GHz EN/IEC 61000-4-3 2.74 V/m (3 V/m) 1.4 GHz...2 GHz EN/IEC 61000-4-3 0.91 V/m (1 V/m) 2 GHz...3 GHz EN/IEC 61000-4-3
Resistance To Magnetic Fields 98.43 A/m (30 A/m) 50/60 Hz EN/IEC 61000-4-8
Resistance To Fast Transients 3 kV power lines (DC) DC)EN/IEC 61000-4-4 2 kV I/O linesEN/IEC 61000-4-4
Surge Withstand 1 kV power lines (DC) differential mode EN/IEC 61000-4-5 DC 1 kV power lines (DC) common mode EN/IEC 61000-4-5 DC
Resist To Conductd Disturbs 10 V 0.15...80 MHz EN/IEC 61000-4-6
Electromagnetic Emission Radiated emissions 50 dBµV/m class A 24 V DC)30…230 Hz IEC 61131-3 Radiated emissions 57 dBµV/m class A 24 V DC)230…1000 Hz IEC 61131-3
Ambient Air Temp For Op 14…131 °F (-10…55 °C) horizontal installation
Ambient Air Temp For Storage -13…158 °F (-25…70 °C)
Documents
Royal Wholesale Electric

5.0

Powered by

Based on 2 User Reviews