Micrologic 5.0 X control unit, for Masterpact MTZ circuit breakers, fixed, LSI protections
LV847283
Micrologic 5.0 X control unit, for Masterpact MTZ circuit breakers, fixed, LSI protections

This Micrologic 5.0 X is an electronic control unit used on Masterpact MTZ1, MTZ2 and MTZ3 fixed circuit breakers. This control unit is compatible with MTZ1 06 to MTZ1 16, MTZ 08 to MTZ2 40, MTZ3 40 to MTZ3 63, all in fixed version. Masterpact MTZ is the last generation of high current air circuit breakers up to 6300 A embedding advanced digital technologies. Masterpact MTZ is designed to protect electrical systems from damage caused by overloads, short circuits and equipment ground faults. It is possible to customize Micrologic X control unit anytime with digital modules to add new protection, measurement or diagnosis functionalities. Micrologic X control units incorporate several channels of communication, including Ethernet, Modbus SL and wireless communication facilities. Micrologic 5.0 X embeds adjustable long time protection against overloads. It provides also adjustable short-time protection and instantaneous protection against short-circuits. With its embedded backlight HMI, Micrologic 5.0 X allows the quick identification of alarm messages. The information processed by the Micrologic 5.0 X may be displayed on the embedded backlight HMI, a smartphone through Bluetooth or NFC and a PC through the USB connection. The protections can be set by means of the embedded display, a smartphone via Bluetooth or with a PC running EcoStruxure Power Commission, and additionally via Ethernet and Modbus SL communication. Masterpact MTZ and Micrologic X are part of EcoStruxure architecture system.

Add to Quote Catalogue
Specifications
Part Number LV847283
UPC 606480811241
UPC11 60648081124
EAN 3606480811241
UNSPSC 39121601
Prop 65 This product can expose you to chemicals including: DINP and DIDP which is known to the State of California to cause Carcinogen and Reproductive harm. For more information go to www.p65warnings.ca.gov
RoHS Compliant Yes
Characteristics
Range Masterpact
Device Short Name Micrologic 5.0 X
Product Or Component Type Control unit
Device Application Equipment protection, monitoring and control
Circuit Breaker Application Distribution IEC standard
Range Compatibility Masterpact MTZ1 circuit breaker Masterpact MTZ2 circuit breaker Masterpact MTZ3 circuit breaker
Poles 3P 4P
Protected Poles 3P 3d 4P 4d 4P 3d 4P 3d + N/2 4P 3d + OSN
Ue Rated Operational Voltage 690 V AC, +/- 10 %
Network Type AC
Network Frequency 50/60 Hz
Trip Unit Technology Electronic
Trip Unit Protection Functions LSI
Protection Type Overload protection (long time) ANSI 49 Instantaneous short-circuit protection ANSI 50 Short time short-circuit protection ANSI 51
Trip Unit Rating 400 A 4000 A 1250 A 2500 A 800 A 6300 A 1600 A 2000 A 3200 A 630 A 1000 A 5000 A
Mounting Mode Fixed
[Ir] Long Time Pick-Up Adjustment Range 0.4...1 x In adjustable in step of 1 A
Long Time Delay Adj Type Adjustable in step of 0.5 s
[Tr] Long-Time Delay Adjustment Range 12.5…600 s 1.5 x Ir 0.5…24 s 6 x Ir 0.7…16.6 s 7.2 x Ir
Thermal Memory Yes
Isd Short-Time Pick-Up Adj 1.5...10 x Ir adjustable in step of 0.5 x Ir embedded HMI 1.5...10 x Ir adjustable in step of 0.1 x Ir Ecoreach software or Masterpact MTZ mobile app
Short-Time Delay Adj Type Adjustable
Tsd Short-Time Delay Adj 0.1…0.4 s I²t=on 0…0.4 s I²t=off
Instt Pick Up Adj Type Ii Adjustable
[Ii] Instantaneous Pick-Up Adjustment Range 2...15 x In adjustable in step of 0.5 x In embedded HMI 2...15 x In adjustable in step of 0.1 x In Ecoreach software or Masterpact MTZ mobile app Ii enable on/off
[Li Mode] Instantaneous Delay Adjustment Range 0 ms fast 20 ms standard
Zone Selective Intlkg Zsi With
Ntw And Machine Diagnosis Type System (HMI) health state overview circuit breaker health state standard) Contacts state circuit breaker health state standard) Micrologic service life circuit breaker health state standard) Tripping cause indication circuit breaker tripping cause standard) Identification card diagnostic data standard) Configured alarms synthesis diagnostic data standard) Monitored function diagnostic data standard) Operation diagnostic data standard) Micrologic test test standard) Protection test test standard) Selectivity test test standard) Trip context information crisis management standard) Operation advanced diagnostic standard) Breaker service life circuit breaker health state standard)
Type Of Measurement Power meter
Energy Management Measurement ,active, reactive and apparent energy (standard) Measurement ,electrical network (standard) Measurement ,energy (standard)
Metering Type Current I1, I2, I3, In, Ig maximum standard) Average voltage Vavg standard) Active power P, P1, P2, P3 standard) Reactive power Q, Q1, Q2, Q3 standard) Apparent power S, S1, S2, S3 standard) Power factor standard) Frequency standard) Total current harmonic distortion THD (I) inst, avg, avg min, avg max fundamental voltage standard) Total current harmonic distortion THD (I) inst, avg, avg min, avg max RMS voltage standard) Voltage V21, V32, V13, V1, V2, V3 instantaneous standard) Voltage V21, V32, V13, V1, V2, V3 minimum standard) Voltage V21, V32, V13, V1, V2, V3 maximum standard) Total voltage harmonic distortion THD (V) inst, avg, avg min, avg max fundamental voltage standard) Total voltage harmonic distortion THD (V) inst, avg, avg min, avg max RMS voltage standard) Demand current I1, I2, I3, In, Iavg standard) Demand power P, Q, S standard)
Measurement Voltage 145.6…828 V AC 50/60 Hz per phase
Frequency Measurement Range 45…250 Hz
Measurement Accuracy Power factor +/- 1 % Active energy Ep IN/OUT/tot +/- 1 % - 10...10 GWh Reactive energy Ep IN/OUT/tot +/- 2 % - 10...10 GVARh Apparent energy Es IN/OUT/tot +/- 1 % - 10...10 GVAh Unbalance current +/- 0.5 % Frequency +/- 0.005 Hz Voltage V21, V32, V13, VLLavg +/- 0.5 % 208...690 x 1.2 V Voltage V21, V32, V13, VLNavg +/- 0.5 % 120...400 x 1.2 V Apparent power S, S1, S2, S3, Sdemand +/- 1 % Active power P, P1, P2, P3, Pdemand +/- 1 % Reactive power Q, Q1, Q2, Q3, Qdemand +/- 2 % Current I1, I2, I3, Iavg, Idemand for MTZ1 +/- 0.5 % 40...1600 x 1.2 A Current I1, I2, I3, Iavg, Idemand for MTZ2 +/- 0.5 % 40...4000 x 1.2 A Current I1, I2, I3, Iavg, Idemand for MTZ3 +/- 0.5 % 80...6300 x 1.2 A
Accuracy Class Class 5 total current harmonic distortion THD (I) Class 0.5 unbalance voltage Class 1 active and reactive energy by pulse counting (+/- W.h, +/- VAR.h) Class 2 total voltage harmonic distortion THD (V)
Display Type LCD display - 128 x 96 pixels
Communication Port Protocol Bluetooth 4.0 LE peer to peer 30 kbit/s NFC peer to peer ISO 15963 USB peer to peer 115 kbauds
Data Recording Data logs Time stamping Alarm logs Min/max of instantaneous values Event logs Maintenance logs
Standards EN/IEC 60947-1 EN/IEC 60092-202 EN/IEC 60947-2 EN/IEC 60255-1 EN/IEC 61010-1
Mounting Location Indoor use only
Environmental Characteristic Wet location not approved for use IEC 61010-1
Electromagnetic Compatibility Electrostatic discharge immunity test IEC 61000-4-2 Susceptibility to electromagnetic fields IEC 61000-4-3 Electrical fast transient/burst immunity test IEC 61000-4-4 1.2/50 µs shock waves immunity test IEC 61000-4-5 Conducted RF disturbances IEC 61000-4-6 Conducted and radiated emissionsA CISPR 22
Overvoltage Category IV IEC 61010-1
Measurement Category Category IV IEC 61010-2-30
Pollution Degree 3 IEC 60947-1
Ambient Air Temp For Op -13…158 °F (-25…70 °C) operating) -31 °F (-35 °C) for start-up of product)
Relative Humidity 95 % 131 °F (55 °C) IEC 60068-2-30
Operating Altitude <= 6561.68 ft (2000 m) without derating <= 13123.36 ft (4000 m) with operational voltage derating 600 V AC <= 16404.2 ft (5000 m) with operational voltage derating 560 V AC
GTIN 03606480811241
Green Premium Status Green Premium product