Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
Micrologic 3.0 X control unit – w/o AAF-w/o com – for drawout Masterpact MTZ UL
LV839213
Micrologic 3.0 X control unit – w/o AAF-w/o com – for drawout Masterpact MTZ UL
Specifications
Part Number LV839213
UNSPSC 39121601
Characteristics
Range Masterpact
Device Short Name Micrologic 3.0 X
Product Or Component Type Control unit
Device Application Equipment protection, monitoring and control
Circuit Breaker Application Distribution UL/ANSI standard
Range Compatibility Masterpact MTZ1 circuit breaker Masterpact MTZ2 circuit breaker Masterpact MTZ3 circuit breaker
Poles 4P 3P
Protected Poles 4P 3d + OSN 4P 3d + N/2 4P 3d 4P 4d 3P 3d
Network Type AC
Network Frequency 50/60 Hz
Trip Unit Technology Electronic
Trip Unit Protection Functions LI
Protection Type Instantaneous short-circuit protection ANSI 50 Overload (long time) ANSI 49
Trip Unit Rating 3000 A 5000 A 3600 A 600 A 2000 A 2500 A 3200 A 1000 A 1600 A 1200 A 6000 A 400 A 4000 A 800 A
Mounting Mode Fixed
[Ir] Long Time Pick-Up Adjustment Range 0.4...1 x In adjustable in step of 1 A
Long Time Delay Adj Type Adjustable in step of 0.5 s
[Tr] Long-Time Delay Adjustment Range 12.5…600 s 1.5 x Ir 0.5…24 s 6 x Ir 0.7…16.6 s 7.2 x Ir
Thermal Memory Yes
Instt Pick Up Adj Type Ii Adjustable
[Ii] Instantaneous Pick-Up Adjustment Range 1.5...12 x In adjustable in step of 0.5 x In embedded HMI 1.5...12 x In adjustable in step of 0.1 x In Ecoreach software or Masterpact MTZ mobile app
[Li Mode] Instantaneous Delay Adjustment Range 20 ms standard
Zone Selective Intlkg Zsi Without
Ntw And Machine Diagnosis Type System (HMI) health state overview circuit breaker health state standard) Contacts state circuit breaker health state standard) Micrologic service life circuit breaker health state standard) Tripping cause indication circuit breaker tripping cause standard) Identification card diagnostic data standard) Configured alarms synthesis diagnostic data standard) Monitored function diagnostic data standard) Operation diagnostic data standard) Micrologic test test standard) Protection test test standard) Selectivity test test standard) Trip context information crisis management standard) Operation advanced diagnostic standard) Breaker service life circuit breaker health state standard)
Type Of Measurement Power meter
Energy Management Measurement ,active, reactive and apparent energy (standard) Measurement ,electrical network (standard) Measurement ,energy (standard)
Metering Type Average voltage Vavg standard) Power factor standard) Frequency standard) Total current harmonic distortion THD (I) inst, avg, avg min, avg max fundamental voltage standard) Total current harmonic distortion THD (I) inst, avg, avg min, avg max RMS voltage standard) Total voltage harmonic distortion THD (V) inst, avg, avg min, avg max fundamental voltage standard) Total voltage harmonic distortion THD (V) inst, avg, avg min, avg max RMS voltage standard) Demand power P, Q, S standard) Current Ia, Ib, Ic, In, Ig maximum standard) Active power P, Pa, Pb, Pc standard) Reactive power Q, Qa, Qb, Qc standard) Apparent power S, Sa, Sb, Sc standard) Voltage Vba, Vcb, Vac, Va, Vb, Vc instantaneous standard) Voltage Vba, Vcb, Vac, Va, Vb, Vc minimum standard) Voltage Vba, Vcb, Vac, Va, Vb, Vc maximum standard) Demand current Ia, Ib, Ic, In, Iavg standard)
Measurement Voltage 145.6 V AC 50/60 Hz per phase 828 V AC 50/60 Hz per phase
Frequency Measurement Range 40…70 Hz
Measurement Accuracy Power factor +/- 1 % Active energy Ep IN/OUT/tot +/- 1 % - 10...10 GWh Reactive energy Ep IN/OUT/tot +/- 2 % - 10...10 GVARh Apparent energy Es IN/OUT/tot +/- 1 % - 10...10 GVAh Unbalance current +/- 0.5 % Frequency +/- 0.005 Hz Voltage Vba, Vcb, Vac, Vllavg +/- 0.5 % 208...690 x 1.2 V Voltage Vba, Vcb, Vac, Vlnavg +/- 0.5 % 120...400 x 1.2 V Apparent power S, Sa, Sb, Sc, Sdemand +/- 1 % Active power P, Pa, Pb, Pc, Pdemand +/- 1 % Reactive power Q, Qa, Qb, Qc, Qdemand +/- 2 % Current Ia, Ib, Ic, Iavg, Idemand for MTZ1 +/- 0.5 % 40...1600 x 1.2 A Current Ia, Ib, Ic, Iavg, Idemand for MTZ2 +/- 0.5 % 40...4000 x 1.2 A Current Ia, Ib, Ic, Iavg, Idemand for MTZ3 +/- 0.5 % 80...6300 x 1.2 A
Accuracy Class Class 5 total current harmonic distortion THD (I) Class 0.5 unbalance voltage Class 1 active and reactive energy by pulse counting (+/- W.h, +/- VAR.h) Class 2 total voltage harmonic distortion THD (V)
Display Type LCD display - 128 x 96 pixels
Communication Port Protocol Bluetooth 4.0 LE peer to peer 30 kbit/s NFC peer to peer 28800 bauds ISO 15963 USB peer to peer 115 kbauds
Data Recording Alarm logs Time stamping Data logs Min/max of instantaneous values Maintenance logs Event logs
Standards EN/IEC 60947-1 EN/IEC 60255-1 EN/IEC 60947-2 EN/IEC 60092-202
Electromagnetic Compatibility Electrostatic discharge immunity test IEC 61000-4-2 Susceptibility to electromagnetic fields IEC 61000-4-3 Electrical fast transient/burst immunity test IEC 61000-4-4 1.2/50 µs shock waves immunity test IEC 61000-4-5 Conducted RF disturbances IEC 61000-4-6 Conducted and radiated emissionsA CISPR 22
Pollution Degree 3 IEC 60947-1
Ambient Air Temp For Op -13…158 °F (-25…70 °C) operating) -31 °F (-35 °C) for start-up of product)
Relative Humidity 95 % 131 °F (55 °C) IEC 60068-2-30
Operating Altitude <= 6561.68 ft (2000 m) without derating <= 13123.36 ft (4000 m) with operational voltage derating 600 V AC <= 16404.2 ft (5000 m) with operational voltage derating 560 V AC
Warranty 18 months
Documents
Royal Wholesale Electric

5.0

Powered by

Based on 2 User Reviews