Micrologic 2.0 X control unit – w/o AAF-w/o com – drawout Masterpact MTZ IEC
LV839212
Micrologic 2.0 X control unit – w/o AAF-w/o com – drawout Masterpact MTZ IEC
Specifications
Part Number LV839212
UNSPSC 39121601
Characteristics
Range Masterpact
Device Short Name Micrologic 2.0 X
Product Or Component Type Control unit
Device Application Equipment protection, monitoring and control
Circuit Breaker Application Distribution IEC standard
Range Compatibility Masterpact MTZ1 circuit breaker Masterpact MTZ2 circuit breaker Masterpact MTZ3 circuit breaker
Poles 3P 4P
Protected Poles 4P 3d + OSN 3P 3d 4P 4d 4P 3d 4P 3d + N/2
Network Type AC
Network Frequency 50/60 Hz
Trip Unit Technology Electronic
Trip Unit Protection Functions LI
Protection Type Instantaneous short-circuit protection ANSI 50 Overload (long time) ANSI 49
Trip Unit Rating 5000 A 1600 A 2000 A 2500 A 630 A 6300 A 1000 A 3200 A 400 A 4000 A 800 A 1250 A
Mounting Mode Fixed
[Ir] Long Time Pick-Up Adjustment Range 0.4...1 x In adjustable in step of 1 A
Long Time Delay Adj Type Adjustable in step of 0.5 s
[Tr] Long-Time Delay Adjustment Range 12.5…600 s 1.5 x Ir 0.5…24 s 6 x Ir 0.7…16.6 s 7.2 x Ir
Thermal Memory Yes
Instt Pick Up Adj Type Ii Adjustable
[Ii] Instantaneous Pick-Up Adjustment Range 1.5...10 x Ir adjustable in step of 0.5 x Ir embedded HMI 1.5...10 x Ir adjustable in step of 0.1 x Ir Ecoreach software or Masterpact MTZ mobile app
[Li Mode] Instantaneous Delay Adjustment Range 20 ms standard
Zone Selective Intlkg Zsi Without
Ntw And Machine Diagnosis Type System (HMI) health state overview circuit breaker health state standard) Contacts state circuit breaker health state standard) Micrologic service life circuit breaker health state standard) Tripping cause indication circuit breaker tripping cause standard) Identification card diagnostic data standard) Configured alarms synthesis diagnostic data standard) Monitored function diagnostic data standard) Operation diagnostic data standard) Micrologic test test standard) Protection test test standard) Selectivity test test standard) Trip context information crisis management standard) Operation advanced diagnostic standard) Breaker service life circuit breaker health state standard)
Type Of Measurement Power meter
Energy Management Measurement ,active, reactive and apparent energy (standard) Measurement ,electrical network (standard) Measurement ,energy (standard)
Metering Type Current I1, I2, I3, In, Ig maximum standard) Average voltage Vavg standard) Active power P, P1, P2, P3 standard) Reactive power Q, Q1, Q2, Q3 standard) Apparent power S, S1, S2, S3 standard) Power factor standard) Frequency standard) Total current harmonic distortion THD (I) inst, avg, avg min, avg max fundamental voltage standard) Total current harmonic distortion THD (I) inst, avg, avg min, avg max RMS voltage standard) Voltage V21, V32, V13, V1, V2, V3 instantaneous standard) Voltage V21, V32, V13, V1, V2, V3 minimum standard) Voltage V21, V32, V13, V1, V2, V3 maximum standard) Total voltage harmonic distortion THD (V) inst, avg, avg min, avg max fundamental voltage standard) Total voltage harmonic distortion THD (V) inst, avg, avg min, avg max RMS voltage standard) Demand current I1, I2, I3, In, Iavg standard) Demand power P, Q, S standard)
Measurement Voltage 145.6 V AC 50/60 Hz per phase 828 V AC 50/60 Hz per phase
Frequency Measurement Range 40…70 Hz
Measurement Accuracy Power factor +/- 1 % Active energy Ep IN/OUT/tot +/- 1 % - 10...10 GWh Reactive energy Ep IN/OUT/tot +/- 2 % - 10...10 GVARh Apparent energy Es IN/OUT/tot +/- 1 % - 10...10 GVAh Unbalance current +/- 0.5 % Frequency +/- 0.005 Hz Voltage V21, V32, V13, VLLavg +/- 0.5 % 208...690 x 1.2 V Voltage V21, V32, V13, VLNavg +/- 0.5 % 120...400 x 1.2 V Apparent power S, S1, S2, S3, Sdemand +/- 1 % Active power P, P1, P2, P3, Pdemand +/- 1 % Reactive power Q, Q1, Q2, Q3, Qdemand +/- 2 % Current I1, I2, I3, Iavg, Idemand for MTZ1 +/- 0.5 % 40...1600 x 1.2 A Current I1, I2, I3, Iavg, Idemand for MTZ2 +/- 0.5 % 40...4000 x 1.2 A Current I1, I2, I3, Iavg, Idemand for MTZ3 +/- 0.5 % 80...6300 x 1.2 A
Accuracy Class Class 5 total current harmonic distortion THD (I) Class 0.5 unbalance voltage Class 1 active and reactive energy by pulse counting (+/- W.h, +/- VAR.h) Class 2 total voltage harmonic distortion THD (V)
Display Type LCD display - 128 x 96 pixels
Communication Port Protocol Bluetooth 4.0 LE peer to peer 30 kbit/s NFC peer to peer 28800 bauds ISO 15963 USB peer to peer 115 kbauds
Data Recording Min/max of instantaneous values Maintenance logs Time stamping Alarm logs Data logs Event logs
Standards EN/IEC 60255-1 EN/IEC 60092-202 EN/IEC 60947-2 EN/IEC 60947-1
Electromagnetic Compatibility Electrostatic discharge immunity test IEC 61000-4-2 Susceptibility to electromagnetic fields IEC 61000-4-3 Electrical fast transient/burst immunity test IEC 61000-4-4 1.2/50 µs shock waves immunity test IEC 61000-4-5 Conducted RF disturbances IEC 61000-4-6 Conducted and radiated emissionsA CISPR 22
Pollution Degree 3 IEC 60947-1
Ambient Air Temp For Op -13…158 °F (-25…70 °C) operating) -31 °F (-35 °C) for start-up of product)
Relative Humidity 95 % 131 °F (55 °C) IEC 60068-2-30
Operating Altitude <= 6561.68 ft (2000 m) without derating <= 13123.36 ft (4000 m) with operational voltage derating 600 V AC <= 16404.2 ft (5000 m) with operational voltage derating 560 V AC
Warranty 18 months