This product is part of the XCS range, an offer of safety switches. The safety switch is an electrical switch that makes or breaks contact in the presence of a magnetic field. It has 2 normally closed + 2 normally opened, slow-break, break before make contacts, normally closed contact with positive opening operation. It is a switch with a rated operational current of 0.75A at 240V AC, 0.55A at 24V DC and a conventional enclosed thermal current of 4A. It is furnished with spring terminals for electrical connection and 3 cable entry tapped for M20 x 1.5 cable gland. The electromagnet interlocking on de-energization and unlocking on energization of solenoid. It offers long mechanical durability which is about 1 million operating cycles. It is an IP66 and IP67 rated product. The key operated turret head limit switch has a slim metal body which is made of Zamak. Its dimensions are 44mm (Width) x 51mm (Depth) x 205mm (Height) and weighs 1.1kg. It is intended as far as safety is concerned all dangerous machines in all sectors are involved. Such as packaging, handling, robotics, machine tools, presses, automotive sector. This product is certified by TÜV, CSA and UL. It meets CSA C22.2 No 14, EN 60947-5-1, EN/ISO 13849-1, EN/IEC 62061, EN 1088/ISO 14119 and UL 508 standards. One of the most comprehensive ranges of industrial safety switches on the market. These safety interlock switches are suitable for protecting operators of potentially dangerous machines with inertia. Safety switches for the protection of operators, by controlling the safe opening and interlocking of guards and covers in your installations.
Brand: Telemecanique
Add to Quote CataloguePart Number | XCSLF2525342 |
---|---|
Country of Origin | ID |
UPC | 606489413330 |
UPC11 | 60648941333 |
EAN | 3606489413330 |
Availability | N |
Lead Time | 28 |
UNSPSC | 39122213 |
ECCN | EAR99 |
HTs Code | 8536509065 |
Prop 65 | This product can expose you to chemicals including: Di-isodecyl phthalate (DIDP) and Diisononyl phthalate (DINP) which is known to the State of California to cause Carcinogen and Reproductive harm. For more information go to www.p65warnings.ca.gov |
RoHS Compliant | Yes |
Discount Schedule | T |
Return Indicator | No |
Depth | 2.01 inch |
Height | 8.07 inch |
Width | 1.73 inch |
Weight | 2.43 pound |
Range Of Product | Preventa Safety detection |
---|---|
Product Or Component Type | Safety switch |
Component Name | XCSLF |
Design | Slim |
Material | Metal |
Head Type | Key operated turret head |
Contacts Type And Composition | 1 NC + 1 NO |
Contact Operation | Slow-break, break before make |
Solenoid Contacts Type Compo | 1 NC + 1 NO slow-break, break before make) |
Cable Entry | 3 entries tapped M20 x 1.5 |
Electromagnet Interlocking | Locking on de-energisation and unlocking on energisation of solenoid |
[Us]&Nbsp;Solenoid&Nbsp;Rated&Nbsp;Supply Voltage | 230 V - 15...10 % |
Cable Outer Diameter | 0.28…0.51 in (7…13 mm) |
Electrical Connection | Spring terminal 1 x 1.5 mm² flexible or solid cable Spring terminal 2 x 0.5 mm² flexible cables with 13 mm bared ends |
Number Of Poles | 2 |
Locking Options Description | With interlocking, locking by solenoid |
Local Signalling | Actuator withdrawn 1 LED orange) Actuator inserted and locked 1 LED green) |
Signalling Circuit Voltage | 230 V |
Positive Opening | With NC contact |
Supply Voltage Type | AC/DC |
Supply Frequency | 50/60 Hz |
Load Factor | 1 |
Signalling Circuit Type | AC |
Mechanical Durability | 1000000 cycles |
Minimum Actuation Speed | 0.03 ft/s (0.01 m/s) |
Maximum Actuation Speed | 1.64 ft/s (0.5 m/s) |
Ie Rated Operational Current | 0.55 A 24 V, DC-13, R300 EN/IEC 60947-5-1 0.75 A 240 V, AC-15, C300 EN/IEC 60947-5-1 |
Ithe Cnvtl Enclosed Therm Crrt | 4 A |
Maximum Load Current | <= 15 A |
Ui Rated Insulation Voltage | 300 VUL 508 300 VCSA C22.2 No 14 250 V 3)EN/IEC 60947-1 |
Uimp Rated Imp Wstd Voltage | 4 kV EN/IEC 60947-5-1 |
Minimum Switching Current | 10 mA at 20 °C |
Minimum Switching Voltage | 17 V |
Short-Circuit Protection | 4 A cartridge fuse gG (gl) 6 A fast blow |
Acttr Forcible Wdrawal Rtc | 3000 N |
Actutr Force For Extractn | 20 N |
Rtc To Mechanical Impact | 9.6 J against the partition 6.4 J without partition |
Operating Rate | 10 cyc/mn for maximum durability |
Safety Level | Can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 Can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 Can reach SIL 3 EN/IEC 61508 |
Safety Reliability Data | B10d = 5500000 value given for a life time of 20 years limited by mechanical or contact wear |
Body Material | Zamak |
Head Material | Zamak |
Depth | 2.01 in (51 mm) |
Height | 8.07 in (205 mm) |
Width | 1.73 in (44 mm) |
Product Weight | 2.43 lb(US) (1.1 kg) |
Standards | UL 508 EN/IEC 60204-1 CSA C22.2 No 14 EN/IEC 62061 EN 1088/ISO 14119 EN/ISO 13849-1 EN/IEC 60947-5-1 |
Product Certifications | TÜV UL CSA |
Protective Treatment | TC |
Ambient Air Temp For Op | -13…140 °F (-25…60 °C) |
Powered by
Based on 2 User Reviews
1619 Boyd St, Santa Ana, CA 92705
(714) 835-6211
(714) 972-2366