This XCSE Key Operated Safety Switch for guard doors with locking by solenoid has an adjustable turret head and a robust red coated rectangular Zamak body with 2 x Pg 13.5 cable gland entries, allowing for flexible installation. It has 3 normally closed simultaneous (slow break) main contacts actuated by key, contact states given when the key is inserted. And it has 1 normally open and 1 normally closed auxiliary contacts actuated by the solenoid, contact states given when the solenoid is not powered. Its B10D reliability data is 5 000 000. Its IP67 degree of protection makes it ideal for heavy duty use in harsh conditions. It also complies with EN/ISO 14119, EN/IEC 60204-1, EN/IEC 60947-5-1, UL 508, CSA C22.2 No 14 standards. When associated and correctly connected to an appropriate safety control unit, it conforms to Category 4, performance level PL e, SIL 3 as described in EN/ISO 13849-1, EN/IEC 61508.
Brand: Telemecanique
Add to Quote CataloguePart Number | XCSE8311 |
---|---|
Country of Origin | ID |
UPC | 785901850144 |
UPC11 | 78590185014 |
EAN | 3389110719567 |
Availability | N |
Lead Time | 43 |
UNSPSC | 39122213 |
ECCN | EAR99 |
HTs Code | 8536509055 |
Prop 65 | This product can expose you to chemicals including: Di-isodecyl phthalate (DIDP) and Diisononyl phthalate (DINP) which is known to the State of California to cause Carcinogen and Reproductive harm. For more information go to www.p65warnings.ca.gov |
RoHS Compliant | Yes |
Discount Schedule | T |
Return Indicator | Yes |
Depth | 1.73 inch |
Height | 5.75 inch |
Width | 3.86 inch |
Weight | 2.51 pound |
Range Of Product | Preventa Safety detection |
---|---|
Product Or Component Type | Safety switch |
Component Name | XCSE |
Design | Rectangular |
Material | Metal |
Head Type | Key operated turret head |
Contacts Type And Composition | 3 NC |
Contact Operation | Slow-break, simultaneous |
Solenoid Contacts Type Compo | 1 NC + 1 NO slow-break, simultaneous) |
Cable Entry | 2 entries tapped Pg 13.5 |
Electromagnet Interlocking | Locking on de-energisation and unlocking on energisation of solenoid |
[Us]&Nbsp;Solenoid&Nbsp;Rated&Nbsp;Supply Voltage | 24 V - 20...10 % |
Cable Outer Diameter | 0.35…0.47 in (9…12 mm) |
Electrical Connection | Terminal 1 x 0.5...2 x 1.5 mm² with or without cable end |
Number Of Poles | 3 |
Locking Options Description | With interlocking, locking by solenoid |
Local Signalling | Guard closed and locked 1 LED green) |
Signalling Circuit Voltage | 24/48 V 20...52 V) |
Positive Opening | With NC contact |
Supply Voltage Type | AC/DC |
Supply Frequency | 50/60 Hz |
Load Factor | 1 |
Power Consumption In Va | 10 VA inrush 10 VA sealed |
Signalling Circuit Type | AC/DC |
Signalling Circuit Consumption | 7 mA |
Mechanical Durability | 1000000 cycles |
Minimum Actuation Speed | 0.03 ft/s (0.01 m/s) |
Maximum Actuation Speed | 1.64 ft/s (0.5 m/s) |
Ie Rated Operational Current | 0.55 A 125 V, DC-13, Q300 EN/IEC 60947-5-1 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 3 A 120 V, AC-15, B300 EN/IEC 60947-5-1 1.5 A 240 V, AC-15, B300 EN/IEC 60947-5-1 |
Ithe Cnvtl Enclosed Therm Crrt | 6 A |
Ui Rated Insulation Voltage | 50 VEN/IEC 60947-1 signalling circuit |
Uimp Rated Imp Wstd Voltage | 6 kV EN/IEC 60947-5-1 |
Protection Type | Overvoltage protection signalling circuit |
Short-Circuit Protection | 10 A cartridge fuse gG (gl) |
Actutr Forcible Withdrawal Rtc | 2000 N |
Actutr Force For Extractn | 20 N |
Operating Rate | 10 cyc/mn for maximum durability |
Safety Level | Can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 Can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 Can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508 |
Safety Reliability Data | B10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear |
Body Material | Zamak |
Head Material | Zamak |
Depth | 1.73 in (44 mm) |
Height | 5.75 in (146 mm) |
Width | 3.86 in (98 mm) |
Product Weight | 2.51 lb(US) (1.14 kg) |
Standards | EN/IEC 60204-1 EN/IEC 60947-5-1 CSA C22.2 No 14 EN/ISO 12100 UL 508 EN 1088/ISO 14119 |
Product Certifications | UL CSA |
Protective Treatment | TC |
Ambient Air Temp For Op | -13…104 °F (-25…40 °C) |
Ambient Air Temp For Storage | -40…158 °F (-40…70 °C) |