Metal safety switch XCSE – 3 NC – slow break – 2 entries tapped Pg 13 – 24 V
XCSE8311
Metal safety switch XCSE – 3 NC – slow break – 2 entries tapped Pg 13 – 24 V

This XCSE Key Operated Safety Switch for guard doors with locking by solenoid has an adjustable turret head and a robust red coated rectangular Zamak body with 2 x Pg 13.5 cable gland entries, allowing for flexible installation. It has 3 normally closed simultaneous (slow break) main contacts actuated by key, contact states given when the key is inserted. And it has 1 normally open and 1 normally closed auxiliary contacts actuated by the solenoid, contact states given when the solenoid is not powered. Its B10D reliability data is 5 000 000. Its IP67 degree of protection makes it ideal for heavy duty use in harsh conditions. It also complies with EN/ISO 14119, EN/IEC 60204-1, EN/IEC 60947-5-1, UL 508, CSA C22.2 No 14 standards. When associated and correctly connected to an appropriate safety control unit, it conforms to Category 4, performance level PL e, SIL 3 as described in EN/ISO 13849-1, EN/IEC 61508.

Brand: Telemecanique

Add to Quote Catalogue
Specifications
Part Number XCSE8311
Country of Origin ID
UPC 785901850144
UPC11 78590185014
EAN 3389110719567
Availability N
Lead Time 43
UNSPSC 39122213
ECCN EAR99
HTs Code 8536509055
Prop 65 This product can expose you to chemicals including: Di-isodecyl phthalate (DIDP) and Diisononyl phthalate (DINP) which is known to the State of California to cause Carcinogen and Reproductive harm. For more information go to www.p65warnings.ca.gov
RoHS Compliant Yes
Discount Schedule T
Return Indicator Yes
Depth 1.73 inch
Height 5.75 inch
Width 3.86 inch
Weight 2.51 pound
Characteristics
Range Of Product Preventa Safety detection
Product Or Component Type Safety switch
Component Name XCSE
Design Rectangular
Material Metal
Head Type Key operated turret head
Contacts Type And Composition 3 NC
Contact Operation Slow-break, simultaneous
Solenoid Contacts Type Compo 1 NC + 1 NO slow-break, simultaneous)
Cable Entry 2 entries tapped Pg 13.5
Electromagnet Interlocking Locking on de-energisation and unlocking on energisation of solenoid
[Us]&Nbsp;Solenoid&Nbsp;Rated&Nbsp;Supply Voltage 24 V - 20...10 %
Cable Outer Diameter 0.35…0.47 in (9…12 mm)
Electrical Connection Terminal 1 x 0.5...2 x 1.5 mm² with or without cable end
Number Of Poles 3
Locking Options Description With interlocking, locking by solenoid
Local Signalling Guard closed and locked 1 LED green)
Signalling Circuit Voltage 24/48 V 20...52 V)
Positive Opening With NC contact
Supply Voltage Type AC/DC
Supply Frequency 50/60 Hz
Load Factor 1
Power Consumption In Va 10 VA inrush 10 VA sealed
Signalling Circuit Type AC/DC
Signalling Circuit Consumption 7 mA
Mechanical Durability 1000000 cycles
Minimum Actuation Speed 0.03 ft/s (0.01 m/s)
Maximum Actuation Speed 1.64 ft/s (0.5 m/s)
Ie Rated Operational Current 0.55 A 125 V, DC-13, Q300 EN/IEC 60947-5-1 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 3 A 120 V, AC-15, B300 EN/IEC 60947-5-1 1.5 A 240 V, AC-15, B300 EN/IEC 60947-5-1
Ithe Cnvtl Enclosed Therm Crrt 6 A
Ui Rated Insulation Voltage 50 VEN/IEC 60947-1 signalling circuit
Uimp Rated Imp Wstd Voltage 6 kV EN/IEC 60947-5-1
Protection Type Overvoltage protection signalling circuit
Short-Circuit Protection 10 A cartridge fuse gG (gl)
Actutr Forcible Withdrawal Rtc 2000 N
Actutr Force For Extractn 20 N
Operating Rate 10 cyc/mn for maximum durability
Safety Level Can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 Can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 Can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508
Safety Reliability Data B10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear
Body Material Zamak
Head Material Zamak
Depth 1.73 in (44 mm)
Height 5.75 in (146 mm)
Width 3.86 in (98 mm)
Product Weight 2.51 lb(US) (1.14 kg)
Standards EN/IEC 60204-1 EN/IEC 60947-5-1 CSA C22.2 No 14 EN/ISO 12100 UL 508 EN 1088/ISO 14119
Product Certifications UL CSA
Protective Treatment TC
Ambient Air Temp For Op -13…104 °F (-25…40 °C)
Ambient Air Temp For Storage -40…158 °F (-40…70 °C)