Part Number | XCSE8323 |
---|---|
Country of Origin | FR |
UPC | 389110719734 |
UPC11 | 38911071973 |
EAN | 3389110719734 |
Availability | N |
Lead Time | 40 |
UNSPSC | 39122213 |
ECCN | EAR99 |
HTs Code | 8536509055 |
Discount Schedule | T |
Return Indicator | No |
Depth | 1.73 inch |
Height | 5.75 inch |
Width | 3.86 inch |
Weight | 2.51 pound |
Range Of Product | Preventa Safety detection |
---|---|
Product Or Component Type | Safety switch |
Component Name | XCSE |
Design | Rectangular |
Material | Metal |
Head Type | Key operated turret head |
Contacts Type And Composition | 3 NC |
Contact Operation | Slow-break, simultaneous |
Solenoid Contacts Type Compo | 1 NC + 1 NO slow-break, simultaneous) |
Cable Entry | 2 entries tapped 1/2" NPT |
Electromagnet Interlocking | Locking on de-energisation and unlocking on energisation of solenoid |
[Us]&Nbsp;Solenoid&Nbsp;Rated&Nbsp;Supply Voltage | 48 V - 20...10 % |
Electrical Connection | Terminal 1 x 0.5...2 x 1.5 mm² with or without cable end |
Number Of Poles | 3 |
Locking Options Description | With interlocking, locking by solenoid |
Local Signalling | Guard open/guard closed and locked 2 LEDs green or orange) |
Signalling Circuit Voltage | 24/48 V 20...52 V) |
Positive Opening | With NC contact |
Supply Voltage Type | AC/DC |
Supply Frequency | 50/60 Hz |
Load Factor | 1 |
Power Consumption In Va | 10 VA inrush 10 VA sealed |
Signalling Circuit Type | AC/DC |
Signalling Circuit Consumption | 7 mA |
Mechanical Durability | 1000000 cycles |
Minimum Actuation Speed | 0.03 ft/s (0.01 m/s) |
Maximum Actuation Speed | 1.64 ft/s (0.5 m/s) |
Ie Rated Operational Current | 0.55 A 125 V, DC-13, Q300 EN/IEC 60947-5-1 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 3 A 120 V, AC-15, B300 EN/IEC 60947-5-1 1.5 A 240 V, AC-15, B300 EN/IEC 60947-5-1 |
Ithe Cnvtl Enclosed Therm Crrt | 6 A |
Ui Rated Insulation Voltage | 50 VEN/IEC 60947-1 signalling circuit |
Uimp Rated Imp Wstd Voltage | 6 kV EN/IEC 60947-5-1 |
Protection Type | Overvoltage protection signalling circuit |
Short-Circuit Protection | 10 A cartridge fuse gG (gl) |
Actutr Forcible Withdrawal Rtc | 2000 N |
Actutr Force For Extractn | 20 N |
Operating Rate | 10 cyc/mn for maximum durability |
Safety Level | Can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 Can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 Can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508 |
Safety Reliability Data | B10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear |
Body Material | Zamak |
Head Material | Zamak |
Depth | 1.73 in (44 mm) |
Height | 5.75 in (146 mm) |
Width | 3.86 in (98 mm) |
Product Weight | 2.51 lb(US) (1.14 kg) |
Standards | EN/IEC 60947-5-1 EN/ISO 12100 UL 508 EN/IEC 60204-1 EN 1088/ISO 14119 CSA C22.2 No 14 |
Product Certifications | UL CSA |
Protective Treatment | TC |
Ambient Air Temp For Op | -13…104 °F (-25…40 °C) |
Ambient Air Temp For Storage | -40…158 °F (-40…70 °C) |
Vibration Resistance | 5 gn 10…500 Hz)IEC 60068-2-6 |