Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
Metal safety switch XCSE – 2NC+1NO – slow break – 2 entries tapped Pg 13- 24V
XCSE731121
Metal safety switch XCSE – 2NC+1NO – slow break – 2 entries tapped Pg 13- 24V
Specifications
Part Number XCSE731121
Country of Origin FR
UPC 785901537724
UPC11 78590153772
EAN 3389110956764
Availability N
Lead Time 21
UNSPSC 39122213
ECCN EAR99
HTs Code 8536509055
Prop 65 This product can expose you to chemicals including: Di-isodecyl phthalate (DIDP) and Diisononyl phthalate (DINP) which is known to the State of California to cause Carcinogen and Reproductive harm. For more information go to www.p65warnings.ca.gov
RoHS Compliant Yes
Discount Schedule T
Return Indicator No
Depth 1.73 inch
Height 5.75 inch
Width 3.86 inch
Weight 2.51 pound
Characteristics
Range Of Product Preventa Safety detection
Product Or Component Type Safety switch
Component Name XCSE
Design Rectangular
Material Metal
Head Type Key operated turret head
Contacts Type And Composition 2 NC + 1 NO
Contact Operation Slow-break, break before make
Solenoid Contacts Type Compo 1 NC + 1 NO slow-break, simultaneous)
Cable Entry 2 entries tapped Pg 13.5
Electromagnet Interlocking Locking on de-energisation and unlocking on energisation of solenoid
[Us]&Nbsp;Solenoid&Nbsp;Rated&Nbsp;Supply Voltage 24 V - 20...10 %
Cable Outer Diameter 0.35…0.47 in (9…12 mm)
Electrical Connection Terminal 1 x 0.5...2 x 1.5 mm² with or without cable end
Number Of Poles 3
Locking Options Description With interlocking, locking by solenoid
Local Signalling Guard open/guard closed and locked 2 LEDs green or orange)
Signalling Circuit Voltage 24/48 V 20...52 V)
Positive Opening With NC contact
Supply Voltage Type AC/DC
Supply Frequency 50/60 Hz
Load Factor 1
Power Consumption In Va 10 VA inrush 10 VA sealed
Signalling Circuit Type AC/DC
Signalling Circuit Consumption 7 mA
Mechanical Durability 1000000 cycles
Minimum Actuation Speed 0.03 ft/s (0.01 m/s)
Maximum Actuation Speed 1.64 ft/s (0.5 m/s)
Ie Rated Operational Current 0.55 A 125 V, DC-13, Q300 EN/IEC 60947-5-1 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 3 A 120 V, AC-15, B300 EN/IEC 60947-5-1 1.5 A 240 V, AC-15, B300 EN/IEC 60947-5-1
Ithe Cnvtl Enclosed Therm Crrt 6 A
Ui Rated Insulation Voltage 50 VEN/IEC 60947-1 signalling circuit
Uimp Rated Imp Wstd Voltage 6 kV EN/IEC 60947-5-1
Protection Type Overvoltage protection signalling circuit
Short-Circuit Protection 10 A cartridge fuse gG (gl)
Actutr Forcible Withdrawal Rtc 2000 N
Actutr Force For Extractn 20 N
Operating Rate 10 cyc/mn for maximum durability
Safety Level Can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 Can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 Can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508
Safety Reliability Data B10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear
Body Material Zamak
Head Material Zamak
Depth 1.73 in (44 mm)
Height 5.75 in (146 mm)
Width 3.86 in (98 mm)
Product Weight 2.51 lb(US) (1.14 kg)
Standards EN/ISO 12100 UL 508 EN/IEC 60204-1 EN 1088/ISO 14119 CSA C22.2 No 14 EN/IEC 60947-5-1
Product Certifications CSA UL
Protective Treatment TC
Ambient Air Temp For Op -13…104 °F (-25…40 °C)
Ambient Air Temp For Storage -40…158 °F (-40…70 °C)
Documents
Royal Wholesale Electric

5.0

Powered by

Based on 2 User Reviews