Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
MAN-STARTER SHORT CIR CONTACT 575VAC 1
GVAM11
MAN-STARTER SHORT CIR CONTACT 575VAC 1

TeSys GV auxiliary contact block, for motor circuit breakers GV2 and GV3. 1C/O contact for short circuit signaling. Rated for operation up to 2A/240V AC and 1A/60V DC. To be installed on left-hand side of the circuit breaker (1 block mounting maximum), connection by screw clamp terminals. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).

Add to Quote Catalogue
Specifications
Part Number GVAM11
Country of Origin CZ
UPC 785901212423
UPC11 78590121242
EAN 3389110343564
Availability S
Lead Time 3
UNSPSC 39121521
ECCN EAR99
HTs Code 8536509065
Prop 65 This product can expose you to chemicals including: Antimony oxide & Antimony trioxide which is known to the State of California to cause Carcinogen harm. For more information go to www.p65warnings.ca.gov
RoHS Compliant Yes
Discount Schedule I11
Return Indicator Yes
Depth 2.60 inch
Height 3.50 inch
Width 0.37 inch
Weight 0.12 pound
Characteristics
Range TeSys
Device Short Name GVAM
Product Or Component Type Auxiliary contact block
Product Compatibility GV2L GV2ME GV2RT GV3L GV2P GV3P GV2LE
Range Compatibility GV2 GV2 circuit breaker GV3 GV3P circuit breaker GV3 GV3L circuit breaker
Mounting Location Left side
Auxiliary Contacts Operation Short-circuit signal 1 C/O
Pole Contact Composition 1 C/O
Connections - Terminals screw clamp terminals 1 0.00…0.00 in² (1…2.5 mm²)solid screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)solid screw clamp terminals 1 0.00…0.00 in² (0.75…2.5 mm²)flexible without cable end screw clamp terminals 2 0.00…0.00 in² (0.75…2.5 mm²)flexible without cable end screw clamp terminals 2 0.00…0.00 in² (0.75…1.5 mm²)flexible with cable end screw clamp terminals 1 0.00…0.00 in² (0.75…1.5 mm²)flexible with cable end
Ui Rated Insulation Voltage 690 V IEC 60947-1 300 V UL 508 300 V CSA C22.2 No 14
Ue Rated Operational Voltage 24...240 V AC 24...60 V DC
Ith Cnvtl Free Air Therm Crrt 2.5 A fault signalling
Protection Type GB2CB... circuit breaker GG fuse 10 A
Mechanical Durability 100000 cycles
Minimum Switching Current 5 mA
Minimum Switching Voltage 17 V
Rated Opr Power In VA 36 VA 24 V AC-14 1000 cycles 1.5 A 48 VA 48 V AC-14 1000 cycles 1 A 72 VA 110…127 V AC-14 1000 cycles 0.5 A 72 VA 230…240 V AC-14 1000 cycles 0.3 A
Rated Opr Power In W 120 W 240 V DC-13 100000 cycles 140 W 110 V DC-13 100000 cycles 140 W 24 V DC-13 100000 cycles 180 W 60 V DC-13 100000 cycles 240 W 48 V DC-13 100000 cycles 15 W 48 V DC-13 1000 cycles 24 W 24 V DC-13 1000 cycles 9 W 60 V DC-13 1000 cycles
Tightening Torque 12.39 lbf.in (1.4 N.m) screw clamp terminals
Height 3.50 in (89 mm)
Width 0.37 in (9.3 mm)
Depth 2.60 in (66 mm)
Product Weight 0.12 lb(US) (0.055 kg)
Environmental Characteristic Normal environment
Category 22367 - MANUAL STR PROTECTOR - GV2
Discount Schedule I11
GTIN 00785901212423
Nbr. Of Units In Pkg. 1
Country Of Origin CZ
Green Premium Status Green Premium product
REACh Free Of SVHC Yes
EU RoHs Directive Compliant
Toxic Heavy Metal Free Yes
Mercury Free Yes
WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Warranty 18 months
Documents
Royal Wholesale Electric

5.0

Powered by