Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
Limit switch XCKMR – stay put crossed rods lever 6mm – 2x(2 NC) – slow – Pg13
XCKMR54D1
Limit switch XCKMR – stay put crossed rods lever 6mm – 2x(2 NC) – slow – Pg13
Specifications
Part Number XCKMR54D1
Country of Origin ID
UPC 785901613541
UPC11 78590161354
EAN 3389110681949
Availability S
Lead Time 3
UNSPSC 39122213
ECCN EAR99
HTs Code 8536509055
Prop 65 This product can expose you to chemicals including: Di-isodecyl phthalate (DIDP) and Diisononyl phthalate (DINP) which is known to the State of California to cause Carcinogen and Reproductive harm. For more information go to www.p65warnings.ca.gov
RoHS Compliant Yes
Discount Schedule T
Return Indicator Yes
Depth 2.32 inch
Height 4.65 inch
Width 7.87 inch
Weight 1.21 pound
Characteristics
Range Of Product OsiSense XC
Series Name Special format
Product Or Component Type Limit switch
Product Specific Application For hoisting and mechanical handling applications
Device Short Name XCKMR
Body Type Fixed
Head Type Rotary head
Material Metal
Body Material Zamak
Head Material Zamak
Fixing Mode By the body
Movement Of Operating Head Rotary
Type Of Operator Stay put crossed rods lever metal square rod 6 mm, L = 200 mm
Type Of Approach Lateral approach, 2 directions
Cable Entry 3 entries tapped for Pg 13.5 cable gland 0.35…0.47 in (9…12 mm)
Number Of Poles 4
Contacts Type And Composition 2 x (2 NC)
Contact Operation Slow-break, staggered
Switch Actuation By any moving part
Electrical Connection Screw-clamp terminals 1 x 0.5...2 x 2.5 mm²
Contacts Insulation Form Zb
Number Of Steps 5 electrical positions
Ctct Blk P Direction Ctrl Circ 1 per direction
Positive Opening With
Positive Opening Min Torque 6.64 lbf.in (0.75 N.m)
Minimum Torque For Tripping 4.43 lbf.in (0.5 N.m)
Minimum Actuation Speed 6 m/min
Maximum Actuation Speed 4.92 ft/s (1.5 m/s) actuation point on the rod between 65 and 95 mm
Maximum Displacement Angle -180 ° 180 °
Contact Code Designation A300, AC-15 (Ue = 240 V), Ie = 3 A 10 A EN/IEC 60947-5-1 appendix A Q150, DC-13 (Ue = 125 V), Ie = 0.55 A EN/IEC 60947-5-1 appendix A
Ui Rated Insulation Voltage 300 VUL 508 300 VCSA C22.2 No 14 500 V 3)EN/IEC 60947-1
Resistance Across Terminals 25 MOhm IEC 60255-7 category 3
Uimp Rated Imp Wstd Voltage 6 kV IEC 60664 6 kV EN/IEC 60947-1
Short-Circuit Protection 10 A cartridge fuse gG
Mechanical Durability 2000000 cycles
Width 7.87 in (200 mm)
Height 4.65 in (118 mm)
Depth 2.32 in (59 mm)
Product Weight 1.21 lb(US) (0.55 kg)
Terminals Description ISO n°1 (11-12)NC (21-22)NC
Shock Resistance 50 gn EN/IEC 60068-2-27
Vibration Resistance 25 gn 10…500 Hz)EN/IEC 60068-2-6
IP Degree Of Protection IP66 EN/IEC 60529
IK Degree Of Protection IK07 EN 50102
Electrical Shock Protect Class Class I IEC 60536
Ambient Air Temp For Op -13…158 °F (-25…70 °C)
Ambient Air Temp For Storage -40…185 °F (-40…85 °C)
Protective Treatment TC
Product Certifications UL CCC CSA CE
Standards EN/IEC 60947-5-1 UL 508 CSA C22.2 No 14
Documents
Royal Wholesale Electric

5.0

Powered by

Based on 2 User Reviews