Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
Limit switch XCKM – metal end plunger – 1NC+1NO – snap action – Pg11
XCKM101
Limit switch XCKM – metal end plunger – 1NC+1NO – snap action – Pg11
Specifications
Part Number XCKM101
Country of Origin FR
UPC 785901537267
UPC11 78590153726
EAN 3389118120471
Availability N
UNSPSC 39122213
HTs Code 8536509025
Prop 65 This product can expose you to chemicals including: Di-isodecyl phthalate (DIDP) and Diisononyl phthalate (DINP) which is known to the State of California to cause Carcinogen and Reproductive harm. For more information go to www.p65warnings.ca.gov
RoHS Compliant Yes
Discount Schedule T
Return Indicator No
Depth 1.18 inch
Height 2.52 inch
Width 2.52 inch
Weight 0.62 pound
Characteristics
Range Of Product OsiSense XC
Series Name Standard format
Product Or Component Type Limit switch
Device Short Name XCKM
Body Type Fixed
Head Type Rotary head
Material Metal
Body Material Zamak
Fixing Mode By the body
Movement Of Operating Head Rotary
Type Of Operator Spring return without operating lever
Type Of Approach Lateral approach, 2 directions
Cable Entry 3 entries tapped for Pg 11 cable gland
Number Of Poles 2
Contacts Type And Composition 1 NC + 1 NO
Contact Operation Snap action
Electrical Connection Screw-clamp terminals 1 x 0.34...2 x 1.5 mm²
Contacts Insulation Form Zb
Number Of Steps 1
Positive Opening With
Positive Opening Min Torque 2.21 lbf.in (0.25 N.m)
Minimum Torque For Tripping 0.89 lbf.in (0.1 N.m)
Minimum Actuation Speed 0.01 m/min
Maximum Actuation Speed 4.92 ft/s (1.5 m/s)
Contact Code Designation A300, AC-15 (Ue = 240 V), Ie = 3 A EN/IEC 60947-5-1 appendix A Q300, DC-13 (Ue = 250 V), Ie = 0.27 A EN/IEC 60947-5-1 appendix A
Ithe Cnvtl Enclosed Therm Crrt 10 A AC
Ui Rated Insulation Voltage 300 VUL 508 500 V 3)IEC 60947-1 300 VCSA C22.2 No 14
Resistance Across Terminals 25 MOhm IEC 60255-7 category 3
Uimp Rated Imp Wstd Voltage 6 kV IEC 60664 6 kV IEC 60947-1
Short-Circuit Protection 10 A cartridge fuse gG
Electrical Durability 5000000 cycles, DC-13, inductive, 120 V, 4 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C 5000000 cycles, DC-13, inductive, 24 V, 7 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C 5000000 cycles, DC-13, inductive, 48 V, 10 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C
Mechanical Durability 15000000 cycles
Width 2.52 in (64 mm)
Height 2.52 in (64 mm)
Depth 1.18 in (30 mm)
Product Weight 0.62 lb(US) (0.28 kg)
Terminals Description ISO n°1 (21-22)NC (13-14)NO
Shock Resistance 50 gn 11 ms EN/IEC 60068-2-27
Vibration Resistance 25 gn 10…500 Hz)EN/IEC 60068-2-6
IP Degree Of Protection IP66 EN/IEC 60529
IK Degree Of Protection IK05 EN 50102
Electrical Shock Protect Class Class I IEC 61140 Class I NF C 20-030
Ambient Air Temp For Op -13…158 °F (-25…70 °C)
Ambient Air Temp For Storage -40…158 °F (-40…70 °C)
Protective Treatment TC
Product Certifications UL CSA CCC
Standards EN 60204-1 EN 60947-5-1 UL 508 CSA C22.2 No 14 IEC 60204-1 IEC 60947-5-1
Category 22416 - LIMIT SWITCHES,IEC,XCKL
Discount Schedule T
GTIN 00785901537267
Documents
Royal Wholesale Electric

5.0

Powered by

Based on 2 User Reviews