Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
Limit switch XCKL – thermoplastic roller lever – 1NC+1NO – slow-break – 1/2NPT
XCKL515H7
Limit switch XCKL – thermoplastic roller lever – 1NC+1NO – slow-break – 1/2NPT
Specifications
Part Number XCKL515H7
Country of Origin ID
UPC 785901922001
UPC11 78590192200
EAN 3389118120501
Availability F
Lead Time 5
UNSPSC 39122213
HTs Code 8536509055
Prop 65 This product can expose you to chemicals including: Di-isodecyl phthalate (DIDP) and Diisononyl phthalate (DINP) which is known to the State of California to cause Carcinogen and Reproductive harm. For more information go to www.p65warnings.ca.gov
RoHS Compliant Yes
Discount Schedule T
Return Indicator No
Depth 1.18 inch
Height 2.83 inch
Width 2.05 inch
Characteristics
Range Of Product OsiSense XC
Series Name Standard format
Product Or Component Type Limit switch
Device Short Name XCKL
Body Type Fixed
Head Type Rotary head
Material Metal
Body Material Zamak
Fixing Mode By the body
Movement Of Operating Head Rotary
Type Of Operator Spring return roller lever thermoplastic
Type Of Approach Lateral approach, 2 directions
Cable Entry 1 entry tapped for 1/2" NPT cable gland
Number Of Poles 2
Contacts Type And Composition 1 NC + 1 NO
Contact Operation Slow-break, break before make
Switch Actuation By 30° cam
Electrical Connection Screw-clamp terminals 1 x 0.5...2 x 2.5 mm²
Contacts Insulation Form Zb
Number Of Steps 1
Positive Opening With
Positive Opening Min Torque 2.21 lbf.in (0.25 N.m)
Minimum Torque For Tripping 0.89 lbf.in (0.1 N.m)
Minimum Actuation Speed 6 m/min
Maximum Actuation Speed 4.92 ft/s (1.5 m/s)
Contact Code Designation A300, AC-15 (Ue = 240 V), Ie = 3 A EN/IEC 60947-5-1 appendix A Q300, DC-13 (Ue = 250 V), Ie = 0.27 A EN/IEC 60947-5-1 appendix A
Ithe Cnvtl Enclosed Therm Crrt 10 A AC
Ui Rated Insulation Voltage 300 VUL 508 500 V 3)IEC 60947-1 300 VCSA C22.2 No 14
Resistance Across Terminals 25 MOhm IEC 60255-7 category 3
Uimp Rated Imp Wstd Voltage 6 kV IEC 60664 6 kV IEC 60947-1
Short-Circuit Protection 10 A cartridge fuse gG
Electrical Durability 5000000 cycles, DC-13, inductive, 120 V, 4 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C 5000000 cycles, DC-13, inductive, 24 V, 7 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C 5000000 cycles, DC-13, inductive, 48 V, 10 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C
Mechanical Durability 15000000 cycles
Width 2.05 in (52 mm)
Height 2.83 in (72 mm)
Depth 1.18 in (30 mm)
Terminals Description ISO n°1 (13-14)NO (21-22)NC
Shock Resistance 50 gn 11 ms EN/IEC 60068-2-27
Vibration Resistance 25 gn 10…500 Hz)EN/IEC 60068-2-6
IP Degree Of Protection IP66 EN/IEC 60529
IK Degree Of Protection IK05 EN 50102
Electrical Shock Protect Class Class I IEC 61140 Class I NF C 20-030
Ambient Air Temp For Op -13…158 °F (-25…70 °C)
Ambient Air Temp For Storage -40…158 °F (-40…70 °C)
Protective Treatment TC
Product Certifications CSA UL
Standards UL 508 EN 60947-5-1 IEC 60947-5-1 CSA C22.2 No 14 EN 60204-1 IEC 60204-1
Category 22416-LIMIT SWITCHES,IEC,XCKL
Discount Schedule T
GTIN 00785901922001
Documents
Royal Wholesale Electric

5.0

Powered by

Based on 2 User Reviews