Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
Limit switch body ZCD – compact – 1NC+1NO – snap action – M12 5P
ZCD21M12
Limit switch body ZCD – compact – 1NC+1NO – snap action – M12 5P

This ZCD body/contact assembly with connector has a standard contacts and a Zamak body. It has 1 x NO + 1 x NC snap action contacts and a M12 4-pin connector. It can be matched with any head, actuator or connector from the XCKD, XCKP and XCKT ranges.

Brand: Telemecanique

Add to Quote Catalogue
Specifications
Part Number ZCD21M12
Country of Origin ID
UPC 785901914174
UPC11 78590191417
EAN 3389110190700
Availability S
Lead Time 43
UNSPSC 39122213
HTs Code 8536509055
Prop 65 This product can expose you to chemicals including: Di-isodecyl phthalate (DIDP) and Diisononyl phthalate (DINP) which is known to the State of California to cause Carcinogen and Reproductive harm. For more information go to www.p65warnings.ca.gov
RoHS Compliant Yes
Discount Schedule T
Return Indicator Yes
Depth 1.18 inch
Height 2.56 inch
Width 1.22 inch
Characteristics
Range Of Product OsiSense XC
Series Name Standard compact
Product Or Component Type Limit switch body
Device Short Name ZCD
Design Compact
Body Type Fixed
Associated Head ZCE24 ZCE13 ZCE63 ZCE02 ZCE21 ZCE66 ZCE07 ZCE08 ZCE06 ZCE09 ZCE64 ZCE27 ZCE28 ZCE65 ZCE11 ZCEH0 ZCE01 ZCE05 ZCE14 ZCE67 ZCE29 ZCE10 ZCEH2 ZCE62
Body Material Zamak
Number Of Poles 2
Contacts Type And Composition 1 NC + 1 NO
Contact Operation Snap action
Electrical Connection Male connector M12, 5 pins
Contacts Insulation Form Zb
Contacts Material Silver plated contacts
Positive Opening With
Minimum Actuation Speed 0.03 ft/s (0.01 m/s)
Contact Code Designation B300, AC-15 (Ue = 240 V), Ie = 1.5 A EN/IEC 60947-5-1 appendix A R300, DC-13 (Ue = 250 V), Ie = 0.1 A EN/IEC 60947-5-1 appendix A
Ui Rated Insulation Voltage 300 VUL 508 500 V 3)IEC 60947-1 300 VCSA C22.2 No 14
Resistance Across Terminals 25 mOhm IEC 60255-7 category 3
Uimp Rated Imp Wstd Voltage 6 kV IEC 60664 6 kV IEC 60947-1
Short-Circuit Protection 10 A cartridge fuse gG
Ie Rated Operational Current 3 A 50 V, AC-15 EN/IEC 60947-5-1 appendix A 0.27 A 50 V, DC-13 EN/IEC 60947-5-1 appendix A
Ithe Cnvtl Enclosed Therm Crrt 4 A
Electrical Durability 5000000 cycles, DC-13 24 V, 10 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C 5000000 cycles, DC-13 48 V, 7 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C
Width 1.22 in (31 mm)
Height 2.56 in (65 mm)
Depth 1.18 in (30 mm)
Product Compatibility XCKD
Ambient Air Temp For Op -13…158 °F (-25…70 °C)
Ambient Air Temp For Storage -40…158 °F (-40…70 °C)
Category 22418 - LIMIT SWITCH,IEC,XCKP&XCKT
Discount Schedule T
GTIN 00785901914174
Nbr. Of Units In Pkg. 1
Country Of Origin ID
Green Premium Status Green Premium product
EU RoHs Directive Pro-active compliance (Product out of EU RoHS legal scope)
Mercury Free Yes
Warranty 18 months
Documents