Digital Module “ANSI 27/59 – Under/Over voltage” for Micrologic X
LV850012
Digital Module “ANSI 27/59 – Under/Over voltage” for Micrologic X

This is the digital module “ANSI 27/59 – Under/Over voltage” for Micrologic X trip unit on MasterPact MTZ offer. A digital module is an advanced function that can be uploaded in Micrologic X trip unit at any stage of the product life cycle. Digital modules allow you to customize MasterPact MTZ circuit breaker to your specific needs. The digital modules are available 24/7 on the Schneider Electric GoDigital store (godigital.schneider-electric.com). The upload of the digital modules is made without interrupting power, using EcoStruxure Power Commission software and a USB cable. This digital module allows to trip the circuit breaker trips when the voltage exceeds the settings. For 27-1 and 59-1 the protection picks up when one of the three monitored voltages reaches its upper or lower limit. For 27-2 and 59-2 the protection picks up when the three monitored voltages have reached the upper or lower limits. The Under/Over voltage protection requires the Micrologic X control unit to be supplied by an external 24 V dc power supply. The Micrologic X control unit firmware (greater than or equal to V002.000.xxx) is compatible with this digital module. Earlier firmware versions need to be upgraded. The benefit is to provide the protection of the generators during abnormal or critical situations (load shedding, source changeover, emergency generator starting).

Add to Quote Catalogue
Specifications
Part Number LV850012
UNSPSC 39121601
Characteristics
Range Masterpact
Product Or Component Type Application
Application Description Undervoltage 27 Overvoltage 59
Range Compatibility Masterpact MTZ1 circuit breaker Masterpact MTZ2 circuit breaker Masterpact MTZ3 circuit breaker
Service Description Circuit breaker trips when the voltage exceeds the settings Under/overvoltage protection monitors V12, V23, V31 or V1N, V2N, V3N
Service Benefits Typical actions: load shedding, source changeover, emergency generator starting Protection of the generators Enable action to be initiated to safeguard the operation of the installation
Energy Management Network management (option)
Function Of Module Protection
Protection Type Undervoltage 27/59 option Overvoltage
Software Name EcoStruxure Power Device
EU RoHs Directive Not applicable, out of EU RoHS legal scope