Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
Dark grey station – green flush/red flush pushbuttons Ø22 and red pilot light
XALD363G
Dark grey station – green flush/red flush pushbuttons Ø22 and red pilot light

This Harmony XALD dark grey control station for start/stop function is ideal for your complete control station. It operates with spring return mechanism and uses screw-clamp terminals. This control station with flush push buttons is ideal to control start / stop operation in your machines. Its schematic is clearly distinguishable thanks to clear colors and markings. It is impact resistant, dust resistant, water resistant, corrosion resistant, and vibration resistant thanks to its IP69 / IP67 / IP66 / IP69K, making it ideal for operation in harsh environments. Its wide range of operating temperatures from -40°C to 70°C allows versatility in usage of product. Vibration resistant screw clamp connection terminals ensure high vibration resistance making product suitable installation on high impact machine.

Add to Quote Catalogue
Specifications
Part Number XALD363G
Country of Origin FR
UPC 785901945819
UPC11 78590194581
EAN 3389110114508
Availability N
Lead Time 20
UNSPSC 39122216
ECCN EAR99
HTs Code 8536509031
Prop 65 This product can expose you to chemicals including: Lead and lead compounds which is known to the State of California to cause Carcinogen & Reproductive harm. For more information go to www.p65warnings.ca.gov
RoHS Compliant Yes
Discount Schedule CS2
Return Indicator No
Weight 0.58 pound
Characteristics
Range Of Product Harmony XALD
Product Or Component Type Complete control station
Device Short Name XALD
Product Destination For XB5 Ø 22 mm control and signalling units
Control Station Application Start-Stop function
Colour Of Base Of Enclosure Light grey RAL 7035)
Colour Of Cover Dark grey RAL 7016)
Material Polycarbonate
Operator Profile 2 flush push-buttons - 1 central pilot light
Operators Description Green ''I'' 1 NO - red ''O'' 1 NC
Control Station Composition 1 flush push-button, green 1 NO I 1 flush push-button, red 1 NC O 1 pilot light
Marking Location Marking on push-button
Contact Operation Slow-break
Light Source Integrated and protected LED
Light Source Colour Red
[Us] Rated Supply Voltage 120 V AC
Cable Entry 2 knock-outs for cable entry 0.55 in (14 mm) 2 knock-outs for Pg 13 cable gland and ISO M20 0.47 in (12 mm)
Product Weight 0.58 lb(US) (0.261 kg)
Resistance High Press Washer 1015.26 psi (7000000 Pa) 131 °F (55 °C) 0.1 m
Colour Of Marking Black marking when white caps White marking when green, red or black caps
Positive Opening With EN/IEC 60947-5-1 appendix K
Operating Travel 0.06 in (1.5 mm) NC changing electrical state) 0.10 in (2.6 mm) NO changing electrical state) 0.17 in (4.3 mm) total travel)
Operating Force 3.5 N NC changing electrical state 3.8 N NO changing electrical state
Mechanical Durability 10000000 cycles
Connections - Terminals Screw clamp terminals, <= 2 x 1.5 mm² with cable end EN/IEC 60947-1 Screw clamp terminals, >= 1 x 0.22 mm² without cable end EN/IEC 60947-1
Tightening Torque 7.08…10.62 lbf.in (0.8…1.2 N.m) EN/IEC 60947-1
Shape Of Screw Head Cross Philips no 1 Cross pozidriv No 1 Slotted flat Ø 4 mm Slotted flat Ø 5.5 mm
Contacts Material Silver alloy (Ag/Ni)
Short-Circuit Protection 10 A cartridge fuse gG EN/IEC 60947-5-1
Ith Cnvtl Free Air Therm Crrt 10 A EN/IEC 60947-5-1
Ui Rated Insulation Voltage 600 V 3)EN/IEC 60947-1
Uimp Rated Imp Wstd Voltage 6 kV EN/IEC 60947-1
Ie Rated Operational Current 6 A 120 V, AC-15, A600 EN/IEC 60947-5-1 3 A 240 V, AC-15, A600 EN/IEC 60947-5-1 1.2 A 600 V, AC-15, A600 EN/IEC 60947-5-1 0.55 A 125 V, DC-13, Q600 EN/IEC 60947-5-1 0.27 A 250 V, DC-13, Q600 EN/IEC 60947-5-1 0.1 A 600 V, DC-13, Q600 EN/IEC 60947-5-1
Electrical Durability 1000000 cycles, AC-15, 2 A 230 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C 1000000 cycles, AC-15, 3 A 120 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C 1000000 cycles, AC-15, 4 A 24 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C 1000000 cycles, DC-13, 0.2 A 110 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C 1000000 cycles, DC-13, 0.5 A 24 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C
Electrical Reliability Λ < 10exp(-6) 5 V, 1 mA EN/IEC 60947-5-4 Λ < 10exp(-8) 17 V, 5 mA EN/IEC 60947-5-4
Signalling Type Steady
Current Consumption 14 mA
Service Life 100000 h at rated voltage and 25 °C
Surge Withstand 1 kV IEC 61000-4-5
Protective Treatment TH
Ambient Air Temp For Storage -40…158 °F (-40…70 °C)
Ambient Air Temp For Op -40…158 °F (-40…70 °C)
Overvoltage Category Class II IEC 60536
IP Degree Of Protection IP66 IEC 60529 IP67 IP69 IP69K
Nema Degree Of Protection NEMA 13 NEMA 4X
IK Degree Of Protection IK05 EN 50102
Standards UL 508 EN/IEC 60947-1 EN/IEC 60947-5-4 JIS C8201-5-1 EN/IEC 60947-5-1 EN/IEC 60947-5-5 CSA C22.2 No 14 JIS C8201-1
Vibration Resistance 5 gn 12…500 Hz)IEC 60068-2-6
Shock Resistance 30 gn 18 ms) half sine wave acceleration IEC 60068-2-27 50 gn 11 ms) half sine wave acceleration IEC 60068-2-27
Resistance To Fast Transients 2 kV IEC 61000-4-4