This product is part of the XCS range, an offer of safety limit switches. The coded magnetic switch is an electrical switch that makes or breaks contact in the presence of a magnetic field. It has 2 normally opened, staggered contacts. It has 2 solid-state PNP outputs with 1.5A, 24V DC ratings. It is designed to operate in hazardous environments. It is furnished with a 10m pre-cabled (6 x 0.25mm²) for electrical connection. It supports lateral approach in 9 directions. It offers long electrical life with electrical durability of about 1.2 million operating cycles. It is an IP66, IP67 and IP69K rated product. The casing is made of thermoplastic PBT. Its dimensions are 34mm (Width) x 32mm (Depth) x 100mm (Height) and weighs 0.745kg. It is intended as far as safety is concerned all dangerous machines in all sectors are involved. Such as packaging, handling, robotics, machine tools, presses, automotive sector. This product is certified by CSA, TUV, UL. It meets EN 13849-1, EN/IEC 60947-5-1, EN/IEC 60947-5-2, EN/IEC 60947-5-3, EN/IEC 62061, IEC 61508 and ISO 14119 standards. The coded magnetic switch offers protection of operators by stopping the machine when the actuator attached to the machine guard is withdrawn from the head of the switch. Safety switches for the protection of operators, by controlling the safe opening and interlocking of guards and covers in your installations.
Brand: Telemecanique
Add to Quote CataloguePart Number | XCSDM379110 |
---|---|
Country of Origin | FR |
UPC | 389118307292 |
UPC11 | 38911830729 |
EAN | 3389118307292 |
Availability | N |
Lead Time | 30 |
UNSPSC | 39122213 |
ECCN | EAR99 |
HTs Code | 8536509065 |
Prop 65 | This product can expose you to chemicals including: Di-isodecyl phthalate (DIDP) and Diisononyl phthalate (DINP) which is known to the State of California to cause Carcinogen and Reproductive harm. For more information go to www.p65warnings.ca.gov |
RoHS Compliant | Yes |
Discount Schedule | T |
Return Indicator | No |
Depth | 1.26 inch |
Height | 3.94 inch |
Width | 1.34 inch |
Weight | 1.64 pound |
Range Of Product | Preventa Safety detection |
---|---|
Product Or Component Type | Coded magnetic system |
Component Name | XCSDM3 |
Design | Rectangular |
Size | 100 x 34 x 32 mm |
Contacts Type And Composition | 1 NO + 1 NO |
Material | Plastic |
Electrical Connection | Pre-cabled |
Cable Composition | 6 x 0.25 mm² |
Cable Length | 32.81 ft (10 m) |
Ohmic Cable Resistance | 900 mOhm |
Local Signalling | Green, orange and red 1 LED |
Approach Directions | 9 directions |
Ue Rated Operational Voltage | 24 V DC - 20...10 %) |
Ui Rated Insulation Voltage | 36 V DC |
Cable Outer Diameter | 0.24 in (6.1 mm) |
Type Of Output Stage | Solid-state, PNP |
Safety Outputs | 2 outputs 1.5 A, 24 V, DC |
Sa Assured Operating Distance | 0.39 in (10 mm) |
[Sar]Assured Tripping Distance | 0.79 in (20 mm) |
Minimum Actuation Speed | 0.03 ft/s (0.01 m/s) |
Uimp Rated Imp Wstd Voltage | 2.5 kV EN/IEC 60947-5-1 |
Protection Type | Overload and short-circuit protection |
Switching Frequency | 3 Hz |
Time Delay | 100 ms activation |
Discordance Time | 2 s |
[Hft] Hardware Fault Tolerance | 1 |
Tightening Torque | < 1.8 N.m |
Installed Device | 32 maximum with 2 m long cable |
Marking | CE |
Safety Level | Can reach category 3 correctly wired EN/ISO 13849-1 Can reach PL = d correctly wired EN/ISO 13849-1 Can reach SIL 2 correctly wired EN/IEC 61508 |
Safety Reliability Data | HFT = 1 MTTFd = 182 years PFD = 1.15E-5 PFH = 3.94E-9 SF = 92.5 % |
Enclosure Material | Thermoplastic PBT |
Cable Material | PVC |
Depth | 1.26 in (32 mm) |
Height | 3.94 in (100 mm) |
Width | 1.34 in (34 mm) |
Product Weight | 1.64 lb(US) (0.745 kg) |
Standards | EN 13849-1 EN/IEC 60947-5-1 EN/IEC 60947-5-3 EN/IEC 60947-5-2 EN/IEC 62061 IEC 61508 ISO 14119 |
Product Certifications | UL TÜV CSA |
Ambient Air Temp For Op | -13…158 °F (-25…70 °C) |
Ambient Air Temp For Storage | -40…185 °F (-40…85 °C) |
Vibration Resistance | 10 gn 10…500 Hz)IEC 60068-2-6 |
Shock Resistance | 30 gn 11 ms IEC 60068-2-27 |
Sensitivity To Magnetic Fields | 0.5 mT |
Electrical Shock Protect Class | Class III EN/IEC 61140 |
IP Degree Of Protection | IP66 IEC 60529 IP67 IEC 60529 IP69K DIN 40050 |