This is an integrated solution for monitoring multi-circuits and mains by using a single meter. The meter is designed for use in new build and is used for critical power operations in data centres and energy management in buildings. It offers class 1 (1 %) power and energy system accuracy (100A solid core current transformers) on all branch channels. The BCPM monitors both the 42 branch circuits and mains values, incoming power and energy. All to provide information on the complete Power Distribution Unit. Full alarming capabilities ensure that potential issues are dealt with before they become problems. Communication enabled with serial connection for either Modbus RTU or BACnet MS/TP, and an Ethernet connection for Modbus TCP, BACnet IP and SNMP. The meter need to be powered by a 100V AC to 277V AC supply source. Include 2 21-CTs board strips with 1inch (26mm) spacing between each CT connectors, for 42 circuits. The device dimensions are 353mm in width, 253mm in height, 71mm in depth and weight 1.5 kilograms.
Brand: Veris Industries
Add to Quote CataloguePart Number | BCPME142S |
---|---|
Availability | N |
Lead Time | 15 |
UNSPSC | 83101808 |
Prop 65 | This product can expose you to chemicals including: Lead and lead compounds which is known to the State of California to cause Carcinogen & Reproductive harm. For more information go to www.p65warnings.ca.gov |
Discount Schedule | PL1 |
Return Indicator | No |
Height | 5.75 inch |
Width | 11.34 inch |
Weight | 3.31 pound |
Range | PowerLogic |
---|---|
Product Name | PowerLogic BCPM |
Product Or Component Type | Multi-circuit energy meter |
Device Short Name | BCPME |
Model Type | Advanced + ethernet |
Power Monitoring | Basic instrumentation |
Energy Management | Sub billing and cost allocation |
Device Application | Sub billing |
Power Quality Analysis | voltage sag and swell detection |
Type Of Measurement | Voltage Current Frequency Active power Power factor Active energy |
[Us] Rated Supply Voltage | 90...277 V AC 50/60 Hz +/- 1 % |
Network Frequency | 50 Hz 60 Hz |
Current Transformer Input | 42 solid core CT 100 A |
Update Time | 1.8 s |
Measurement Voltage | 90…277 V phase to neutral 150…480 V phase to phase |
Measurement Accuracy | Branch current 2 % 0.25…2 A Branch current 1 % 2…100 A Mains current 3 % 1…100 % Mains current 3 % 2…100 % Voltage 1 % 90…277 V |
Sampling Rate | 256 samples/cycle |
Connection Pitch | 1.02 in (26 mm) |
Provided Equipment | 42 x current transformer 2 x cables |
Communication Port Protocol | Modbus RTU BACnet IP BACnet MS/TP Modbus TCP SNMP v2 |
Communication Port Support | RS485 Ethernet |
Communication Of Data | Low current alarm High current alarm Over voltage alarm High-high current alarm Low-low current alarm Under voltage alarm |
Mounting Mode | Panel-mounted |
Mounting Support | Panel Enclosure |
Relative Humidity | 0…95 % 32…140 °F (0…60 °C) |
Ambient Air Temp For Storage | -40…158 °F (-40…70 °C) |
Operating Altitude | 9842.52 ft (3000 m) |
Standards | IEC 61036 ANSI C12.1 UL 508 EN 61010 |
Product Certifications | UL |
Width | 11.34 in (288 mm) |
Height | 5.75 in (146 mm) |
Product Weight | 3.31 lb(US) (1.5 kg) |
Category | 09793 - PLOGIC BRANCH CIRCUIT BCPM & MCM |
Discount Schedule | PL1 |
Nbr. Of Units In Pkg. | 1 |
EU RoHs Directive | Compliant |
WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |