TeSys GV auxiliary contact block, for motor circuit breakers GV5, GV6, GV7. 1C/O contact, it performs Open/Close OF function or trip alarm SD function or electrical fault indication, depending of its location in the circuit breaker. Rated for operation up to 5A/690V AC and 2A/110V DC, low level contacts with minimum operational conditions 5mA/12V. To be plugged inside the circuit breaker, 4 cavities are possible (2 for OF functions, 1 for SD function, 1 for electrical fault), connection by screw terminals. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).

Add to Quote Catalogue
Specifications
Part Number GV7AB11
Country of Origin FR
UPC 785901617488
UPC11 78590161748
EAN 3389110617481
Availability N
Lead Time 17
UNSPSC 39121521
ECCN EAR99
HTs Code 8538908180
Prop 65 This product can expose you to chemicals including: Antimony oxide & Antimony trioxide which is known to the State of California to cause Carcinogen harm. For more information go to www.p65warnings.ca.gov
RoHS Compliant Yes
Discount Schedule I11
Return Indicator No
Weight 0.03 pound
Characteristics
Range TeSys
Device Short Name GV7AB
Product Or Component Type Auxiliary contact block
Device Application Signalling
Range Compatibility TeSys GV5 motor circuit breaker TeSys GV6 motor circuit breaker TeSys GV7 motor circuit breaker
Auxiliary Contact Composition 1 C/O
Auxiliary Contacts Type Low level contacts
Auxiliary Contacts Operation Instantaneous
Ith Cnvtl Free Air Therm Crrt 6 A IEC 60947-5-1
Ue Rated Operational Voltage <= 690 V AC 50/60 Hz <= 110 V DC
Ie Rated Operational Current 5 A AC-12 Ue: <= 690 V IEC 60947-5-1 5 A AC-15 Ue: <= 48 V IEC 60947-5-1 4 A AC-15 Ue: 110...127 V IEC 60947-5-1 3 A AC-15 Ue: 230...240 V IEC 60947-5-1 2.5 A AC-15 Ue: 380...440 V IEC 60947-5-1 0.1 A AC-15 Ue: 660...690 V IEC 60947-5-1 2 A DC-12 Ue: <= 48 V IEC 60947-5-1 0.5 A DC-12 Ue: 110 V IEC 60947-5-1 0.5 A DC-14 Ue: <= 24 V IEC 60947-5-1 0.25 A DC-14 Ue: 48 V IEC 60947-5-1 0.1 A DC-14 Ue: 110 V IEC 60947-5-1
Minimum Switching Current 5 mA
Minimum Switching Voltage 12 V
Ui Rated Insulation Voltage 690 V IEC 60947-1
Protection Type GG fuse 10 A maximum GB2CB... circuit breaker 10 A maximum
Mechanical Durability 50000 cycles
Mounting Location Inside the circuit breaker
Connections - Terminals screw clamps terminals 1 0.00 in² (1.5 mm²)flexible with cable end screw clamps terminals 1 0.00 in² (1.5 mm²)flexible without cable end screw clamps terminals 1 0.00 in² (1.5 mm²)rigid
Product Weight 0.03 lb(US) (0.015 kg)
Category 22366 - MAN STR PROTECTORS-GV1/GV3
Discount Schedule I11
GTIN 00785901617488
Nbr. Of Units In Pkg. 1
Country Of Origin FR
EU RoHs Directive Compliant
Toxic Heavy Metal Free Yes
Mercury Free Yes
WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Warranty 18 months