Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
Analog IO module, TeSys island, 2 inputs, 1 output
TPRAN2X1
Analog IO module, TeSys island, 2 inputs, 1 output

TeSys island analog IO module, 2 analog inputs, 1 analog output. Connected to a TPRBC bus coupler it is used for advanced control functions (TeSys avatars). Two analog inputs can be configured for measurement of voltage (-10/+10V, 0/+10V), current (0-20mA, 4-20mA) or temperature probes (Ni, Pt, thermocouples). One analog output can be configured for driving voltage source (-10/+10V, 0/+10V) or current source (0-20mA, 4-20mA). Mounting on DIN rail together with the other modules of the TeSys island configuration. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).

Add to Quote Catalogue
Specifications
Part Number TPRAN2X1
Country of Origin ID
UPC 606489832704
UPC11 60648983270
EAN 3606489832902
Availability N
Lead Time 16
ECCN EAR99
HTs Code 8517620090
RoHS Compliant Yes
Discount Schedule I12
Return Indicator Yes
Depth 4.49 inch
Height 4.65 inch
Width 0.98 inch
Weight 0.38 pound
Characteristics
Range TeSys
Product Name TeSys island
Device Short Name TPRAN
Product Or Component Type Analog IO module
Device Presentation IO module providing 2 analog inputs and 1 analog output Enabling advanced control functions in a TeSys island system Operational only when connected to a bus coupler TPRBC
Function Of Module Measurement of voltage, current or temperature on 2 configurable analog inputs Driving voltage or current source on 1 configurable analog output
Product Compatibility TPRBC bus coupler
Analogue Input Number 2
Analogue Input Type Current 4...20 mA Current 0...20 mA Voltage 0...10 V Voltage - 10...10 V Temperature probe - 60...180 °C Ni 100 Temperature probe - 60...180 °C Ni 1000 Temperature probe -200...+850 °C Pt 100 Temperature probe - 200...600 °C Pt 1000 Thermocouple - 200...1000 °C thermocouple J Thermocouple - 200...1300 °C thermocouple K Thermocouple 0...1760 °C thermocouple R Thermocouple 0...1760 °C thermocouple S Thermocouple 0...1820 °C thermocouple B Thermocouple - 200...400 °C thermocouple T Thermocouple - 200...1300 °C thermocouple N Thermocouple - 200...800 °C thermocouple E Thermocouple 0...2315 °C thermocouple C
Measurement Accuracy +/- 0.1 % of full scale +/- 0.1 % of full scale +/- 0.1 % of full scale +/- 0.1 % of full scale in positive temperature range +/- 0.4 % of full scale in negative temperature range
Analogue Input Resolution 15 bits + sign
Input Impedance <= 50 Ohm current >= 1 MOhm voltage >= 1 MOhm thermocouple >= 1 MOhm temperature probe
Analogue Output Number 1 isolated
Analogue Output Type Current 4...20 mA Current 0...20 mA Voltage 0...10 V Voltage - 10...10 V
Analogue Output Resolution 4...20 mA, full scale 0...20 mA, full scale 0...10 V, full scale - 10...10 V, full scale
Type Of Cable Twisted shielded pairs cable <98.43 ft (30 m) input/output
Local Signalling DS (device status) 1 LED green/red)
Us Rated Supply Voltage 24 V DC supplied by the bus coupler
Current Consumption 160 mA
Power Dissipation In W 0.5 W maximum
Uimp Rated Imp Wstd Voltage 0.5 kV IEC 61010-1
Standards IEC 61010-2-201 UL 61010-2-201 CSA C22.2 No 61010-2-201
Product Certifications CSA UL EAC (pending)
Mounting Mode Horizontal and vertical 35 mm symmetrical rail)
Connections - Terminals Input/output circuit removable spring terminal block 8 0.00…0.00 in² (0.2…2.5 mm²) AWG 24...AWG 14)rigid Input/output circuit removable spring terminal block 8 0.00…0.00 in² (0.2…2.5 mm²) AWG 24...AWG 14)flexible without cable end Input/output circuit removable spring terminal block 8 0.00…0.00 in² (0.25…2.5 mm²) AWG 22...AWG 14)flexible with cable end
Width 0.98 in (25 mm)
Height 4.65 in (118 mm)
Depth 4.49 in (114 mm)
Product Weight 0.38 lb(US) (0.172 kg)
Ambient Air Temp For Storage -13…158 °F (-25…70 °C)
Ambient Air Temp For Op 14…140 °F (-10…60 °C)
Relative Humidity 5…95 %
Operating Altitude 0...6561.68 ft (0...2000 m) without derating
IP Degree Of Protection IP20
Pollution Degree 2
Protective Treatment TC
Fire Resistance 1760 °F (960 °C) UL 94
Shock Resistance 15 gn 11 ms) IEC 60068-2-27
Vibration Resistance 1.5 mm peak to peak 3…13 Hz) IEC 60068-2-6 1 gn 13…200 Hz) IEC 60068-2-6
Electromagnetic Compatibility Electrostatic discharge immunity test, level 3 8 kV air, 6 kV contact)EN/IEC 61000-4-2) Radiated RF fields, level 3 10 V/m)EN/IEC 61000-4-3) Fast transients immunity test, level 3 2 kV)EN/IEC 61000-4-4) Surge immunity test, level 3 2 kV)EN/IEC 61000-4-5)
Category 22353 - TESYS ISLAND AUXILIARY DEVICES
Discount Schedule I12
GTIN 03606489832704
Nbr. Of Units In Pkg. 1
Country Of Origin ID
EU RoHs Directive Compliant
Mercury Free Yes
WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Halogen Content Performance Halogen free plastic parts product
Warranty 18 months
Documents