Part Number | 9013FHG42J59M1 |
---|---|
Country of Origin | MX |
UPC | 785901658375 |
UPC11 | 78590165837 |
EAN | 0785901658375 |
Availability | N |
UNSPSC | 39122210 |
HTs Code | 9032200000 |
Prop 65 | This product can expose you to chemicals including: Di-isodecyl phthalate (DIDP) and Diisononyl phthalate (DINP) which is known to the State of California to cause Carcinogen and Reproductive harm. For more information go to www.p65warnings.ca.gov |
Discount Schedule | CP7I |
Return Indicator | No |
Depth | 3.76 inch |
Height | 3.71 inch |
Width | 3.1 inch |
Weight | 1 pound |
Range Of Product | Square D Pumptrol |
---|---|
Pressure Sensor Name | 9013FH |
Pressure Sensor Size | 200 psi (1378.95 kPa) |
Value Of Setting | Off at 175 psi |
Electrical Circuit Type | Power circuit |
Product Specific Application | Control small electrically driven air compressors |
Quantity Per Set | 1 |
Type Of Packing | Individual |
Pressure Sensor Type | Electromechanical pressure switch |
Controlled Fluid | Air -22…257 °F (-30…125 °C)) |
Adj Range On Rising Pressure | 100…200 psi (689.48…1378.95 kPa) |
Approximate Fixed Differential | 40 psi (275.79 kPa) |
Destruction Pressure | 220 psi (1516.85 kPa) |
Pressure Actuator | Diaphragm |
Pressure Swt Type Of Operation | Regulation between 2 thresholds |
Type Of Scale | Fixed differential |
Setting | Internal |
Local Display | Without |
Contacts Type And Composition | 2 NC, snap action, DPST-DB, Form YY |
Cable Entry Number | 2 0.88 in (22.35 mm) cable entries with 0.84 in across flats UL 508 |
Electrical Connection | Screw-clamp terminals 10 AWG Screw-clamp terminals 5.261 mm² |
Fluid Connection Type | 0.25 inch NPSF internal UL 508 |
Short-Circuit Protection | 20 A cartridge fuse gG |
Materials In Contact Wth Fluid | Zinc plated steel or equivalent flange Nitrile (Buna-N) or equivalent rubber diaphragm |
Material | Polypropylene cover Noryl thermoplastic resin or equivalent cover |
Operating Position | Any position |
Motor Power kW | 1.5 kW 2 hp)230 V AC, 1 phase 1.1 kW 1.5 hp)115 V AC, 1 phase 1.5 kW 2 hp)115 V AC, 3 phase 2.2 kW 3 hp)230 V AC, 3 phase 0.75 kW 1 hp)460 V AC, 3 phase 0.75 kW 1 hp)575 V AC, 3 phase |
Electrical Durability | 100000 cycles 10 cyc/mn |
Mechanical Durability | 300000 cycles |
Terminal Block Type | 4 terminals |
Operating Rate | 10 cyc/mn |
Ui Rated Insulation Voltage | 575 V UL 508 |
Product Weight | 1 lb(US) (0.45 kg) |
Repeat Accuracy | +/- 3 % |
Terminals Description ISO n°1 | L1-T1 L2-T2 |
Width | 3.1 in (78.74 mm) |
Height | 3.71 in (94.23 mm) |
Depth | 3.76 in (95.50 mm) |
Factory Modification | Maintained manual cut-out lever (AUTO-OFF) |
Standards | CE UL 508 |
Ambient Air Temp For Op | -33…257 °F (-36…125 °C) |
Ambient Air Temp For Storage | -33…257 °F (-36…125 °C) |
Protective Treatment | None |
Nema Degree Of Protection | NEMA 1 UL 50 |
IP Degree Of Protection | IP20 IEC 60529 |
Product Certifications | CSA file LR25490 UL listed file E12158 |
Category | 21533 - 9013 FHG (INDIVIDUAL-DISCOUNT CP7I) |
Discount Schedule | CP7I |
GTIN | 00785901658375 |
Nbr. Of Units In Pkg. | 1 |
Powered by
Based on 2 User Reviews
1619 Boyd St, Santa Ana, CA 92705
(714) 835-6211
(714) 972-2366